RI-CTL-MB2B-30 Datasheet, PDF (30/40 Pages) Texas Instruments – Series 2000 Reader System | |||
|
◁ |
General Purpose I/O
2.12 General Purpose I/O
The Control Module provides two I/O ports which can be configured in the following way:
I/O (1)
I/O
0
1
2
3
4
5
6
7
I
I
I
I
I
I
I
I
I
I
I
I
O
O
O
O
O
O
O
O
I
I
I
I
O
O
O
O
O
O
O
O
www.ti.com
(1) I = Input, O = Output
The Control Module firmware configures I/O ports 0 â 3 as Inputs and I/O ports 4 â 7 as Outputs by
default.
S2_Util.exe can be used the reconfigure the system as required.
Please do not exceed the values given under Electrical Characteristics in Chapter 3 of this guide. The pin
assignments for the I/O are shown in Figure 2-21.
These I/O lines are TTL compatible and are connected via a 220 ⦠series resistor to the input terminals of
the 82C55A CMOS Programmable Peripheral Interface IC (Port C).
Figure 2-21. General Purpose I/O Port Pin Assignment
30
Installation
SCBU044 (11-09-21-077) â January 2008
Submit Documentation Feedback
|
▷ |