Figure 2-17. Master/Slave Synchronization With Acknowledgment
Table 2-16. Master/Slave Synchronization With Acknowledgement
Jumper 12 (JP12)
Jumper 13 (JP13)
Jumper 14 (JP14)
UNIT(1)
Control Module MASTER
Closed
Closed (1)
Closed
UNIT(2) to UNIT(n-1)
Control Module SLAVES
Open
Open
Open
UNIT(n)
Control Module
SLAVE
Closed
Closed (1)
Closed
(1) If the distance between Unit(1) and Unit(n) is less than approximately 400 m, Jumper 13 (JP13) can be left out.
2.9 Input/Reset
The Control Module provides two general purpose input lines. Each of these input lines is pulled up to
VCC2 (+ 5V) by a 100 kΩ resistor.
The Reset-terminal at this connector can be used to reset external circuitry or to reset the Control Module
externally. Figure 2-18 shows an example to reset the Control Module with an external push button.
28
Installation
Figure 2-18. Input/Reset Connection
SCBU044 (11-09-21-077) – January 2008
Submit Documentation Feedback