RI-CTL-MB2B-30 Datasheet, PDF (27/40 Pages) Texas Instruments – Series 2000 Reader System
www.ti.com
Synchronization Interface
Figure 2-16. Synchronization Interface Connection
Table 2-14. Master/Slave Synchronization without Acknowledgement
Jumper 12 (JP12)
Jumper 13 (JP13)
Jumper 14 (JP14)
UNIT(1)
Control Module
MASTER
Closed
Open
Closed
UNIT(2) to UNIT(n-1)
Control Module
SLAVES
Open
Open
Open
UNIT(n)
Control Module
SLAVE
Closed
Closed (1)
Closed
(1) If the distance between Unit(1) and Unit(n) is less than approximately 400 m, Jumper 13 (JP13) can be left out.
Table 2-15. Triggered Synchronization without Acknowledgement
Jumper 12 (JP12)
Jumper 13 (JP13)
Jumper 14 (JP14)
UNIT(1)
Trigger Unit
Termination not required
Termination not required
Termination not required
UNIT(2) to UNIT(n-1)
Control Module
MASTERS
Open
Open
Open
UNIT(n)
Control Module
MASTER
Closed
Closed (1)
Closed
(1) If the distance between Unit(1) and Unit(n) is less than approximately 400 m, Jumper 13 (JP13) can be left out.
2.8.4 Master/Slave Synchronization With Acknowledgement
Figure 2-17 shows the way that the Control Module must be connected for Master/Slave synchronization
with acknowledgement. The individual SW configuration (Master or Slave) is shown in Table 2-16 which
also explains the setting of jumpers 12, 13 and 14 (JP12, JP13 and JP14).