English
Language : 

LM4F111E5QR Datasheet, PDF (314/1114 Pages) Texas Instruments – Microcontroller
System Control
Register 57: 32/64-Bit Wide General-Purpose Timer Run Mode Clock Gating
Control (RCGCWTIMER), offset 0x65C
The RCGCWTIMER register provides software the capability to enable and disable 3264-bit timer
modules in Run mode. When enabled, a module is provided a clock and accesses to module registers
are allowed. When disabled, the clock is disabled to save power and accesses to module registers
generate a bus fault. This register provides the same capability as the legacy Run Mode Clock
Gating Control Register n RCGCn registers specifically for the timer modules and has the same
bit polarity as the corresponding RCGCn bits.
32/64-Bit Wide General-Purpose Timer Run Mode Clock Gating Control (RCGCWTIMER)
Base 0x400F.E000
Offset 0x65C
Type R/W, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
R5
R4
R3
R2
R1
R0
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:6
5
Name
reserved
R5
Type
RO
R/W
Reset
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
32/64-Bit Wide General-Purpose Timer 5 Run Mode Clock Gating Control
Value Description
1 Enable and provide a clock to 32/64-bit wide general-purpose
timer module 5 in Run mode.
0 32/64-bit wide general-purpose timer module 5 is disabled.
4
R4
R/W
0
32/64-Bit Wide General-Purpose Timer 4 Run Mode Clock Gating Control
Value Description
1 Enable and provide a clock to 32/64-bit wide general-purpose
timer module 4 in Run mode.
0 32/64-bit wide general-purpose timer module 4 is disabled.
3
R3
R/W
0
32/64-Bit Wide General-Purpose Timer 3 Run Mode Clock Gating Control
Value Description
1 Enable and provide a clock to 32/64-bit wide general-purpose
timer module 3 in Run mode.
0 32/64-bit wide general-purpose timer module 3 is disabled.
314
April 25, 2012
Texas Instruments-Advance Information