English
Language : 

TLE202X_16 Datasheet, PDF (24/80 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2022 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLE2022M
TLE2022AM
TLE2022BM
TA†
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
150 500
700
120 300
450
70 150
μV
300
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
μV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.006
0.006
0.006
μV/mo
IIO
Input offset current
25°C
Full range
0.5
6
10
0.4
6
10
0.3
6
nA
10
IIB
Input bias current
25°C
Full range
35
70
90
33
70
90
30
70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
VOM +
VOM −
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
RL = 10 kΩ
−15 −15.3
−15 −15.3
−15 −15.3
25°C
to
to
to
to
to
to
13.5
14
13.5
14
13.5
14
V
− 15
− 15
− 15
Full range
to
to
to
13.2
13.2
13.2
25°C
14 14.3
14 14.3
14 14.3
V
Full range 13.9
13.9
13.9
25°C
−13.7 −14.1
−13.7 −14.1
−13.7 −14.1
V
Full range −13.6
− 13.6
− 13.6
Large-signal differential
AVD
voltage amplification
VO = ± 10 V,
25°C
0.8
4
RL = 10 kΩ Full range
0.8
1
7
1
1.5
10
1.5
V/μV
CMRR Common-mode rejection ratio VIC = VICRmin,
RS = 50 Ω
25°C
Full range
95 106
91
97 109
100 112
dB
93
96
Supply-voltage rejection ratio
25°C
100 115
103 118
105 120
kSVR
(ΔVCC ± /ΔVIO)
VCC ± = ± 2.5 V to ± 15 V
Full range
95
dB
98
100
ICC
ΔICC
Supply current
Supply current change over
operating temperature range
VO = 0,
No load
25°C
Full range
Full range
550 700
700
60
550 700
700
60
550 700
μA
700
60
μA
† Full range is −55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius
equation and assuming an activation energy of 0.96 eV.