English
Language : 

TLE202X_16 Datasheet, PDF (10/80 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2021 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLE2021C
MIN TYP MAX
TLE2021AC
MIN TYP MAX
TLE2021BC
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 500
750
80 200
500
40 100
μV
200
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
μV/°C
Input offset voltage long-term drift
(see Note 4)
VIC = 0, RS = 50 Ω
25°C
0.006
0.006
0.006
μV/mo
IIO
Input offset current
25°C
Full range
0.2
6
10
0.2
6
10
0.2
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
90
25
70
90
25
70
nA
90
−15 −15.3
−15 −15.3
−15 −15.3
25°C
to
to
to
to
to
to
VICR Common-mode input voltage range
RS = 50 Ω
13.5
14
13.5
14
13.5
14
V
− 15
−15
−15
Full range
to
to
to
13.5
13.5
13.5
VOM+
VOM −
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
25°C
14 14.3
14 14.3
14 14.3
V
Full range 13.9
13.9
13.9
RL = 10 kΩ
25°C −13.7 −14.1
−13.7 −14.1
−13.7 −14.1
V
Full range −13.7
− 13.7
− 13.7
Large-signal differential
AVD
voltage amplification
VO = ± 10 V,
RL = 10 kΩ
25°C
Full range
1 6.5
1
1
6.5
1
1
6.5
1
V/μV
CMRR Common-mode rejection ratio
VIC = VICR min,
RS = 50 Ω
25°C
100 115
Full range
96
100 115
96
100 115
96
dB
kSVR
Supply-voltage rejection ratio
(ΔVCC /ΔVIO)
VCC ± = ± 2.5 V
to ± 15 V
25°C
Full range
105 120
100
105 120
100
105 120
dB
100
ICC
ΔICC
Supply current
Supply-current change over
operating temperature range
VO = 0, No load
25°C
Full range
Full range
240 350
350
6
240 350
350
6
240 350
μA
350
6
μA
† Full range is 0°C to 70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.