TLE2024 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLE2024I
TLE2024AI
TLE2024BI
TA†
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
1000
750
500
μV
Full range
1200
950
700
αVIO
Temperature coefficient of input
offset voltage
Full range
2
2
2
μV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.006
0.006
0.006
μV/mo
IIO
Input offset current
25°C
Full range
0.6
6
10
0.5
6
10
0.4
6
nA
10
IIB
Input bias current
25°C
Full range
50
70
90
45
70
90
40
70
nA
90
VICR
Common-mode input voltage
range
RS = 50 Ω
−15 −15.3
−15 −15.3
−15 −15.3
25°C
to
to
to
to
to
to
13.5
14
13.5
14
13.5
14
V
− 15
− 15
− 15
Full range
to
to
to
13.2
13.2
13.2
VOM +
VOM −
Maximum positive peak output
voltage swing
Maximum negative peak output
voltage swing
RL = 10 kΩ
25°C
13.8 14.1
13.9 14.2
14 14.3
V
Full range 13.7
13.7
13.8
25°C
−13.7 −14.1
−13.7 −14.1
−13.7 −14.1
V
Full range −13.6
− 13.6
− 13.6
Large-signal differential
AVD
voltage amplification
25°C
0.4
2
VO = ± 10 V,
RL = 10 kΩ Full range
0.4
0.8
4
0.8
1
7
1
V/μV
CMRR Common-mode rejection ratio
VIC = VICRmin,
RS = 50 Ω
25°C
Full range
92 102
88
94 105
90
97 108
dB
93
Supply-voltage rejection ratio
25°C
98 112
100 115
103 117
kSVR
(ΔVCC ± /ΔVIO)
VCC ± = ± 2.5 V to ± 15 V
Full range
93
95
dB
98
ICC
ΔICC
Supply current
Supply current change over
operating temperature range
VO = 0,
No load
25°C
Full range
Full range
1050 1400
1400
50
1050 1400
1400
50
1050 1400
μA
1400
50
μA
† Full range is − 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation