English
Language : 

TLE202X_16 Datasheet, PDF (19/80 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2024 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLE2024I
TLE2024AI
TLE2024BI
TA†
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
1100
1300
850
1050
600
μV
800
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
μV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.005
0.005
0.005
μV/mo
IIO
Input offset current
25°C
Full range
0.6
6
10
0.5
6
10
0.4
6
nA
10
IIB
Input bias current
25°C
Full range
45
70
90
40
70
90
35
70
nA
90
VICR
Common-mode input voltage
range
RS = 50 Ω
0 −0.3
0 −0.3
0 −0.3
25°C
to
to
to
to
to
to
3.5
4
3.5
4
3.5
4
V
0
0
0
Full range
to
to
to
3.2
3.2
3.2
VOM +
VOM −
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
RL = 10 kΩ
25°C
Full range
25°C
Full range
3.9 4.2
3.9 4.2
4 4.3
V
3.7
3.7
3.8
0.7 0.8
0.95
0.7 0.8
0.95
0.7 0.8
V
0.95
Large-signal differential
AVD
voltage amplification
VO = 1.4 V to 4 V,
25°C
RL = 10 kΩ Full range
0.2 1.5
0.1
0.3 1.5
0.1
0.4 1.5
0.1
V/μV
CMRR Common-mode rejection ratio VIC = VICRmin,
RS = 50 Ω
25°C
Full range
80
90
80
82
92
82
85
95
dB
85
kSVR
Supply-voltage rejection ratio
(ΔVCC± /ΔVIO)
VCC ± = ± 2.5 V to ± 15 V
25°C
Full range
98 112
93
100 115
95
103 117
98
dB
ICC
ΔICC
Supply current
Supply current change over
operating temperature range
VO = 0,
No load
25°C
Full range
Full range
800 1200
1200
30
800 1200
1200
30
800 1200
μA
1200
30
μA
† Full range is − 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation