TLE2022 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise noted)
PARAMETER
VIO
Input offset voltage
TEST CONDITIONS
TA†
25°C
Full range
TLE2022C
MIN TYP MAX
150 500
700
TLE2022AC
MIN TYP MAX
120 300
450
TLE2022BC
MIN TYP MAX
70 150
300
UNIT
μV
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
μV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.006
0.006
0.006
μV/mo
IIO
Input offset current
25°C
Full range
0.5
6
10
0.4
6
10
0.3
6
nA
10
IIB
Input bias current
25°C
Full range
35
70
90
33
70
90
30
70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
−15 −15.3
−15 −15.3
−15 −15.3
25°C
to
to
to
to
to
to
13.5
14
13.5
14
13.5
14
V
− 15
− 15
− 15
Full range
to
to
to
13.5
13.5
13.5
VOM +
VOM −
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
RL = 10 kΩ
25°C
14 14.3
14 14.3
14 14.3
V
Full range 13.9
13.9
13.9
25°C
−13.7 −14.1
−13.7 −14.1
−13.7 −14.1
V
Full range −13.7
− 13.7
− 13.7
Large-signal differential
AVD
voltage amplification
25°C
0.8
4
VO = ± 10 V,
RL = 10 kΩ Full range
0.8
1
7
1
1.5
10
1.5
V/μV
CMRR Common-mode rejection ratio VIC = VICRmin,
RS = 50 Ω
25°C
Full range
95 106
91
97 109
100 112
dB
93
96
Supply-voltage rejection ratio
25°C
100 115
103 118
105 120
kSVR
(ΔVCC ± /ΔVIO)
VCC ± = ± 2.5 V to ± 15 V
Full range
95
dB
98
100
ICC
ΔICC
Supply current
Supply current change over
operating temperature range
VO = 0,
No load
25°C
Full range
Full range
550 700
700
9
550 700
700
9
550 700
μA
700
9
μA
† Full range is 0°C to 70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius