English
Language : 

TLE202X_16 Datasheet, PDF (22/80 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2021 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLE2021M
TLE2021BM
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 500
1000
40 100
μV
200
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
μV/°C
Input offset voltage long-term drift (see Note 4)
IIO
Input offset current
VIC = 0,
RS = 50 Ω
25°C
25°C
Full range
0.006
0.2
6
10
0.006
0.2
μV/mo
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
90
25
70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
−15 −15.3
−15 −15.3
25°C
to
to
to
to
13.5
14
13.5
14
V
− 15
−15
Full range
to
to
13.2
13.2
VOM +
VOM −
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
RL = 10 kΩ
25°C
14 14.3
14 14.3
V
Full range 13.8
13.8
25°C −13.7 −14.1
−13.7 −14.1
V
Full range −13.6
− 13.6
Large-signal differential
AVD
voltage amplification
VO = ± 10 V,
25°C
1 6.5
RL = 10 kΩ
Full range
0.5
1 6.5
0.5
V/μV
CMRR Common-mode rejection ratio
25°C
100 115
100 115
VIC = VICRmin,
RS = 50 Ω
Full range
96
dB
96
kSVR
Supply-voltage rejection ratio
(ΔVCC ± /ΔVIO)
25°C
105 120
105 120
VCC ± = ± 2.5 V to ± 15 V
Full range 100
100
dB
ICC
ΔICC
Supply current
Supply current change over
operating temperature range
VO = 0,
No load
25°C
Full range
Full range
200 300
300
10
200 300
μA
300
10
μA
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation