SPWS011A − MARCH 1995 − REVISED AUGUST 1995
PARAMETER MEASUREMENT INFORMATION
FPA-slave timing: write cycle
tM is the cycle time of one-eighth of a local-memory cycle (20.83 ns minimum).
NO.
84 Setup time, address on MAX0, MAX2 before MBCLK1 falling edge, FPA-slave read
85 Hold time, address on MAX0, MAX2 after MBCLK1 falling edge, FPA-slave read
86 Setup time, valid address before MBCLK1 falling edge, FPA-slave read
87 Hold time, valid address after MBCLK1 falling edge, FPA-slave read
96 Setup time, valid data/parity after MBCLK1 falling edge, FPA-slave write
97 Hold time, valid data/parity after MBCLK1 falling edge, FPA-slave write
98 Setup time, MDDIR high after MBCLK1 falling edge, FPA-slave write
99 Hold time, MDDIR high after MBCLK1 falling edge, FPA-slave read
MIN
10
0
10
0
tM − 15
tM
tM − 15
tM
M8 M1 M2 M3 M4 M5 M6 M7 M8 M1
tM
MAX
MBCLK1
84
85
UNIT
ns
ns
ns
ns
ns
ns
ns
ns
MAX0, MAX2
Address
MAXPH, MAXPL,
MADL0 −MADL7,
MADH0 −MADH7
MDDIR
86
87
Address
99
98
97
96
Data
In
Figure 10. FPA-Slave Timing: Write Cycle