English
Language : 

BQ4050 Datasheet, PDF (18/53 Pages) Texas Instruments – CEDV Gas Gauge and Protection Solution
bq4050
SLUSC67A – MARCH 2016 – REVISED MARCH 2016
www.ti.com
6.34 Timing Requirements: SMBus XL
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
MIN
NOM
MAX UNIT
fSMBXL
SMBus XL operating
frequency
SLAVE mode
40
400 kHz
tBUF
Bus free time between start
and stop
4.7
µs
tHD(START)
tSU(START)
tSU(STOP)
tTIMEOUT
tLOW
tHIGH
Hold time after (repeated) start
Repeated start setup time
Stop setup time
Error signal detect time
Clock low period
Clock high period
4.0
µs
4.7
µs
4.0
µs
5
20 ms
20 µs
20 µs
tSU(STOP)p
SMBC
TtR
TtBUFT
TtF
tHD(START)
SMBC
TtHIGHT
TtF
TtR
TtLOWT
SMBD
SMBC
SMBD
P
S
Start and Stop Condition
TtTIMEOUT
SMBD
SMBC
tHD(DATA)T
Wait and Hold Condition
tSU(START)T
TtSU(DATA)
SMBD
Timeout Condition
S
Repeated Start Condition
Figure 4. SMBus Timing Diagram
18
Submit Documentation Feedback
Product Folder Links: bq4050
Copyright © 2016, Texas Instruments Incorporated