English
Language : 

BQ4050 Datasheet, PDF (17/53 Pages) Texas Instruments – CEDV Gas Gauge and Protection Solution
www.ti.com
bq4050
SLUSC67A – MARCH 2016 – REVISED MARCH 2016
6.32 Timing Requirements: OCD, SCC, SCD1, SCD2 Current Protection Timing
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
MIN
NOM
MAX UNIT
tOCD
OCD detection
delay time
1
31 ms
ΔtOCD
OCD detection
delay time
program step
2
ms
tSCC
SCC detection
delay time
0
915 µs
ΔtSCC
SCC detection
delay time
program step
61
µs
tSCD1
SCD1 detection AFE PROTECTION CONTROL[SCDDx2] = 0
delay time
AFE PROTECTION CONTROL[SCDDx2] = 1
0
915
µs
0
1850
ΔtSCD1
SCD1 detection
delay time
program step
AFE PROTECTION CONTROL[SCDDx2] = 0
AFE PROTECTION CONTROL[SCDDx2] = 1
61
µs
121
tSCD2
SCD2 detection AFE PROTECTION CONTROL[SCDDx2] = 0
delay time
AFE PROTECTION CONTROL[SCDDx2] = 1
0
458
µs
0
915
ΔtSCD2
SCD2 detection
delay time
program step
AFE PROTECTION CONTROL[SCDDx2] = 0
AFE PROTECTION CONTROL[SCDDx2] = 1
30.5
µs
61
tDETECT
tACC
Current fault
detect time
Current fault
delay time
accuracy
VSRP – VSRN = VT – 3 mV for OCD, SCD1, and SC2,
VSRP – VSRN = VT + 3 mV for SCC
Max delay setting
–10%
160 µs
10%
6.33 Timing Requirements: SMBus
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
MIN
NOM
MAX UNIT
fSMB
SMBus operating frequency SLAVE mode, SMBC 50% duty cycle
fMAS
SMBus master clock
frequency
MASTER mode, no clock low slave extend
10
51.2
100 kHz
kHz
tBUF
Bus free time between start
and stop
4.7
µs
tHD(START)
Hold time after (repeated)
start
4.0
µs
tSU(START)
tSU(STOP)
tHD(DATA)
tSU(DATA)
tTIMEOUT
tLOW
tHIGH
tR
tF
tLOW(SEXT)
Repeated start setup time
Stop setup time
Data hold time
Data setup time
Error signal detect time
Clock low period
Clock high period
Clock rise time
Clock fall time
Cumulative clock low slave
extend time
10% to 90%
90% to 10%
4.7
µs
4.0
µs
300
ns
250
ns
25
35 ms
4.7
µs
4.0
50 µs
1000 ns
300 ns
25 ms
tLOW(MEXT)
Cumulative clock low
master extend time
10 ms
Copyright © 2016, Texas Instruments Incorporated
Product Folder Links: bq4050
Submit Documentation Feedback
17