English
Language : 

BQ4050 Datasheet, PDF (16/53 Pages) Texas Instruments – CEDV Gas Gauge and Protection Solution
bq4050
SLUSC67A – MARCH 2016 – REVISED MARCH 2016
www.ti.com
Electrical Characteristics: Data Flash (continued)
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
tMASSERASE
tPAGEERASE
IFLASHREAD
IFLASHWRITE
IFLASHERASE
Mass-erase time
Page-erase time
Flash-read current
Flash-write current
Flash-erase current
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
40 ms
40 ms
1 mA
5 mA
15 mA
6.31 Electrical Characteristics: OCD, SCC, SCD1, SCD2 Current Protection Thresholds
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
VOCD
OCD detection
threshold voltage range
VOCD = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VOCD = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
–16.6
–8.3
–100
mV
–50
ΔVOCD
OCD detection
threshold voltage
program step
VOCD = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VOCD = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
–5.56
mV
–2.78
VSCC
SCC detection
threshold voltage range
VSCC = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCC = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
44.4
22.2
200
mV
100
ΔVSCC
SCC detection
threshold voltage
program step
VSCC = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCC = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
22.2
mV
11.1
VSCD1
SCD1 detection
threshold voltage range
VSCD1 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD1 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
–44.4
–22.2
–200
mV
–100
ΔVSCD1
SCD1 detection
threshold voltage
program step
VSCD1 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD1 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
–22.2
mV
–11.1
VSCD2
SCD2 detection
threshold voltage range
VSCD2 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD2 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
–44.4
–22.2
–200
mV
–100
ΔVSCD2
SCD2 detection
threshold voltage
program step
VSCD2 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD2 = VSRP – VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
–22.2
mV
–11.1
VOFFSET
OCD, SCC, and SCDx
offset error
Post-trim
–2.5
2.5 mV
VSCALE
OCD, SCC, and SCDx No trim
scale error
Post-trim
–10%
–5%
10%
5%
16