DS90UA101-Q1_14 Datasheet, PDF (17/41 Pages) Texas Instruments – Multi-Channel Digital Audio Link
www.ti.com
Addr
(Hex)
0x07
Name
DES Alias
Bits Field
R/W
7:1 Deserializer Alias RW
ID
0
RSVD
0x08 Slave ID
7:1 Slave ID
RW
0x09 Slave Alias
0
RSVD
7:1 Slave Alias ID
RW
0x0A CRC Errors
0
RSVD
7:0 CRC Error Byte 0 R
0x0B CRC Errors
7:0 CRC Error Byte 1 R
0x0C General Status 7:5
4
3
2
1
Rev-ID
R
RX Lock Detect R
BIST CRC Error R
Status
SCK Detect
R
DES Error
R
0
Link Detect
R
DS90UA101-Q1
Default
(Hex)
0x00
0x00
0x00
0x00
0x00
SNLS441A – JULY 2013 – REVISED SEPTEMBER 2013
Description
This field stores a 7-bit I2C address. Once set, it
configures the Serializer to accept any transaction
designated for the I2C address stored in this field. The
transaction will then be remapped to the I2C address
specified in the DES ID register.
A value of 0 in this field disables I2C access to the
remote Deserializer. Refer to I2C Pass-Through and
Multiple Device Addressing.
Reserved.
This field stores the 7-bit I2C address of the remote slave
attached to the remote Deserializer. If an I2C transaction
(originating from the Serializer side) is addressed to
Slave Alias, the transaction will be remapped to this
address before it is passed across the Bidirectional
Control Channel to the remote Deserializer, where it is
then passed to the remote slave.
A value of 0 in this field disables I2C access to the
remote slave. Refer to I2C Pass-Through and Multiple
Device Addressing.
Reserved.
This field stores a 7-bit I2C address. Once set, it
configures the Serializer to accept any transaction
designated for the I2C address stored in this field. The
transaction will then be remapped to the I2C address
specified in the Slave ID register.
A value of 0 in this field disables I2C access to the
remote slave. Refer to I2C Pass-Through and Multiple
Device Addressing.
Reserved.
Number of back-channel CRC errors during normal
operation.
Least significant byte.
Number of back-channel CRC errors during normal
operation.
Most significant byte.
Revision ID.
0x00: Production.
1: RX LOCKED.
0: RX not LOCKED.
1: CRC errors in BIST mode.
0: No CRC errors in BIST mode.
1: Valid SCK detected.
0: Valid SCK not detected.
1: CRC error is detected during communication with the
Deserializer.
This bit is cleared upon loss of link or assertion of CRC
Error Reset bit in register 0x03[5].
0: No errors detected.
1: Cable link detected.
0: Cable link not detected.
This includes any of the following faults:
— Cable open.
— '+' and '-' shorted.
— Short to GND.
— Short to battery.