English
Language : 

CC3220MOD_017 Datasheet, PDF (15/100 Pages) Texas Instruments – SimpleLink Wi-Fi CERTIFIED Wireless MCU Modules
www.ti.com
CC3220MOD, CC3220MODA
SWRS206B – MARCH 2017 – REVISED AUGUST 2017
4.2 Pin Attributes
Table 4-1 lists the pin descriptions of the CC3220MODx and CC3220MODAx module.
MODULE PIN
NO.
NAME
1
GND
2
GND
3
GPIO10
4
GPIO11
5
GPIO14
6
GPIO15
7
GPIO16
8
GPIO17
9
GPIO12
10
GPIO13
11
GPIO22
12
JTAG_TDI
13
FLASH_SPI_MISO
14
FLASH_SPI_nCS_IN
15
FLASH_SPI_CLK
16
GND
17
FLASH_SPI_MOSI
18
JTAG_TDO
19
GPIO28
21
JTAG_TCK
22
JTAG_TMS
23
SOP2
24
SOP1
25
ANT_SEL1
26
ANT_SEL2
27
GND
28
GND
30
GND
31
RF_BG
32
GND
34
SOP0
35
nRESET
36
VBAT_RESET
37
VBAT1
38
GND
Table 4-1. Module Pin Attributes
TYPE(1)
–
–
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I
I
I
–
O
I/O
I/O
I/O
I/O
–
–
I/O
I/O
–
–
–
I/O
–
–
I
–
Power
–
CC3220 DEVICE
PIN NO.
MODULE PIN DESCRIPTION
–
Ground
–
Ground
1
GPIO(2)
2
GPIO(2)
5
GPIO(2)
6
GPIO(2)
7
GPIO(2)
8
GPIO(2)
3
GPIO(2)
4
GPIO(2)
15
GPIO(2)
16
JTAG TDI input. Leave unconnected if not used on product(2)
–
External Serial Flash Programming: SPI data in
–
External Serial Flash Programming: SPI chip select (active low)
–
External Serial Flash Programming: SPI clock
–
Ground
–
External Serial Flash Programming: SPI data out
17
JTAG TDO output. Leave unconnected if not used on product(1)
18
GPIO(2)
19
JTAG TCK input. Leave unconnected if not used on product.(2)
20
JTAG TMS input. Leave unconnected if not used on product.(2)
21
See Section 6.9.1 for SOP[2:0] configuration modes.
34
See Section 6.9.1 for SOP[2:0] configuration modes.
29
Antenna selection control(2)
30
Antenna selection control(2)
–
Ground
–
Ground
–
Ground
31
2.4-GHz RF input/output
–
Ground
35
See Section 6.9.1 for SOP[2:0] configuration modes.
32
There is an internal, 100 kΩ, pull-up resistor option from the
nRESET pin to VBAT_RESET. Note: VBAT_RESET is not
connected to VBAT1 or VBAT2 within the module. The following
connection schemes are recommended:
• Connect nRESET to a switch, external controller, or host,
only if nRESET will be in a defined state under all operating
37
conditions. Leave VBAT_RESET unconnected to save
power.
• If nRESET cannot be in a defined state under all operating
conditions, connect VBAT_RESET to the main module
power supply (VBAT1 and VBAT2). Due to the internal pull-
up resistor a leakage current of 3.3 V / 100 kΩ is expected.
39
Power supply for the module, must be connected to battery (2.3
V to 3.6 V)
–
Ground
Copyright © 2017, Texas Instruments Incorporated
Terminal Configuration and Functions
15
Submit Documentation Feedback
Product Folder Links: CC3220MOD CC3220MODA