English
Language : 

MSP430FR6979 Datasheet, PDF (119/163 Pages) Texas Instruments – Mixed-Signal Microcontrollers
www.ti.com
MSP430FR6979, MSP430FR69791, MSP430FR6977
MSP430FR6928, MSP430FR6927, MSP430FR69271
SLAS797A – AUGUST 2014 – REVISED MARCH 2015
6.12 Device Descriptors (TLV)
Table 6-41 lists the contents of the device descriptor tag-length-value (TLV) structure for each device type.
Table 6-40 summarizes the Device IDs.
Info Block
Die Record
ADC12B
Calibration
DEVICE
MSP430FR6979
MSP430FR6977
MSP430FR6928
MSP430FR6927
MSP430FR69791
MSP430FR69271
Table 6-40. Device ID
01A05h
081h
081h
081h
081h
081h
081h
DEVICE ID
01A04h
0AEh
0ACh
0B3h
0B2h
0AEh
0B2h
Table 6-41. Device Descriptor Table(1)
DESCRIPTION
Info length
CRC length
CRC value
Device ID
Device ID
Hardware revision
Firmware revision
Die Record Tag
Die Record length
Lot/Wafer ID
Die X position
Die Y position
Test results
MSP430FRxxxx (UART BSL)
ADDRESS
VALUE
01A00h
06h
01A01h
06h
01A02h
per unit
01A03h
per unit
01A04h
01A05h
see Table 6-40
01A06h
per unit
01A07h
per unit
01A08h
08h
01A09h
0Ah
01A0Ah
per unit
01A0Bh
per unit
01A0Ch
per unit
01A0Dh
per unit
01A0Eh
per unit
01A0Fh
per unit
01A10h
per unit
01A11h
per unit
01A12h
per unit
01A13h
per unit
ADC12B Calibration Tag
01A14h
11h
ADC12B Calibration length
ADC Gain Factor(2)
ADC Offset(3)
01A15h
01A16h
01A17h
01A18h
01A19h
10h
per unit
per unit
per unit
per unit
MSP430FRxxxx1 (I2C BSL)
ADDRESS
VALUE
01A00h
06h
01A01h
06h
01A02h
per unit
01A03h
per unit
01A04h
01A05h
see Table 6-40
01A06h
per unit
01A07h
per unit
01A08h
08h
01A09h
0Ah
01A0Ah
per unit
01A0Bh
per unit
01A0Ch
per unit
01A0Dh
per unit
01A0Eh
per unit
01A0Fh
per unit
01A10h
per unit
01A11h
per unit
01A12h
per unit
01A13h
per unit
01A14h
11h
01A15h
01A16h
01A17h
01A18h
01A19h
10h
per unit
per unit
per unit
per unit
(1) NA = Not applicable
per unit = content can differ from device to device
(2) ADC Gain: the gain correction factor is measured using the internal voltage reference with REFOUT=0. Other settings (for example, with
REFOUT = 1) can result in different correction factors.
(3) ADC Offset: the offset correction factor is measured using the internal 2.5-V reference.
Copyright © 2014–2015, Texas Instruments Incorporated
Detailed Description 119
Submit Documentation Feedback
Product Folder Links: MSP430FR6979 MSP430FR69791 MSP430FR6977 MSP430FR6928 MSP430FR6927
MSP430FR69271