Changing the RS232 interface to another COM port (other than COM2) of a personal computer, requires
a change to the COM port assignment in the current version of the terminal emulator.
1.2.3 Programming the Monitor Software Into an Erased EPROM (EVK Only)
The following steps are recommended to program the Monitor into an EPROM after it has been erased:
1. Connect the EVK-PCB to the programming adapter.
2. Connect the programming adapter to the PC.
3. Apply the power supply to the programming adapter (not included in the kit).
4. Start the Program Device software and:
– select the file mon_140.txt in the STK directory
– select with Verify
– select EPROM device
– select the correct parallel port where the adapter is connected
– click on the Program button.
For detailed information see the MSP430 Family Programming Adapter Manual.
Figure 1–4 shows the pop-up that will appear when programming the Monitor software into an erased
EPROM EVK.
Figure 1–4. Programming the Device
1–5