AMC7812B_15 Datasheet, PDF (71/92 Pages) Texas Instruments – 12-Bit Analog Monitoring and Control Solution with Multichannel ADC, DACs, and Temperature Sensors
AMC7812B
www.ti.com
SBAS625A – SEPTEMBER 2013 – REVISED SEPTEMBER 2013
Table 22. Status Register (continued)
BIT
NAME
DEFAULT R/W
DESCRIPTION
Remote temperature reading of D2 when greater than the range flag.
5 D2-High -ALR
0
0 = The local temperature is not greater than the range.
R 1 = The local temperature is greater than the high-bound threshold.
This bit is only checked when D2 is enabled (EN-D2 is '1'); this bit is ignored when EN-D2 is
'0'.
Remote sensor D1 failure flag.
4 D1-FAIL-ALR
0
0 = The sensor is in a normal condition.
R 1 = The sensor is an open-circuit or short-circuit.
This bit is only checked when D1 is enabled (EN-D1 is '1'); this bit is ignored when EN-D1 is
'0'.
Remote sensor D2 failure flag.
3 D2-FAIL-ALR
0
0 = The sensor is in a normal condition.
R 1 = The sensor is an open-circuit or short-circuit.
This bit is only checked when D2 is enabled (EN-D2 is '1'); this is ignored when EN-D2 is
'0'.
2 THERM-ALR
0
Thermal alarm flag.
When the die temperature is equal to or greater than +150°C, the bit is set ('1') and the
R THERM-ALR flag activates. The on-chip temperature sensor (LT) monitors the die
temperature. If LT is disabled, the THERM-ALR bit is always '0'. The hysteresis of this alarm
is 8°C.
1
—
0
R Reserved. Writing to this bit causes no change. Reading this bit returns '0'.
0
—
0
R Reserved. Writing to this bit causes no change. Reading this bit returns '0'.