English
Language : 

MSP430F551X_1 Datasheet, PDF (64/115 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F551x
MSP430F552x
SLAS590D – OCTOBER 2009 – REVISED APRIL 2010
Timer_A
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
Internal: SMCLK, ACLK
fTA
Timer_A input clock frequency
External: TACLK
Duty cycle = 50% ± 10%
VCC
1.8 V/
3.0 V
MIN TYP
tTA,cap
Timer_A capture timing
All capture inputs.
Minimum pulse width required for
capture.
1.8 V/
3.0 V
20
www.ti.com
MAX UNIT
25 MHz
ns
Timer_B
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
Internal: SMCLK, ACLK
fTB
Timer_B input clock frequency
External: TBCLK
Duty cycle = 50% ± 10%
VCC
1.8 V/
3.0 V
MIN TYP
tTB,cap
Timer_B capture timing
All capture inputs.
Minimum pulse width required for
capture.
1.8 V/
3.0 V
20
MAX UNIT
25 MHz
ns
USCI (UART Mode) - recommended operating conditions
PARAMETER
CONDITIONS
fUSCI
USCI input clock frequency
Internal: SMCLK, ACLK
External: UCLK
Duty cycle = 50% ± 10%
fBITCLK
BITCLK clock frequency
(equals baud rate in MBaud)
VCC
MIN TYP MAX UNIT
fSYSTEM MHz
1 MHz
USCI (UART Mode)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
tt
UART receive deglitch time(1)
TEST CONDITIONS
VCC
2.2 V
3V
MIN TYP
50
50
MAX
600
600
UNIT
ns
(1) Pulses on the UART receive input (UCxRX) shorter than the UART receive deglitch time are suppressed. To ensure that pulses are
correctly recognized their width should exceed the maximum specification of the deglitch time.
64
Submit Documentation Feedback
Copyright © 2009–2010, Texas Instruments Incorporated