BQ24262_15 Datasheet, PDF (30/56 Pages) Texas Instruments – bq2426x 3-A, 30-V, Host-Controlled Single-Input, Single-Cell Switched-Mode Li-Ion Battery Charger With Power-Path Management and USB-OTG Support
Not Recommended for New Designs : bq24260, bq24261
bq24260, bq24261, bq24261M, bq24262
SLUSBU4D – DECEMBER 2013 – REVISED APRIL 2015
9.6 Register Maps
9.6.1 Status/Control Register (READ/WRITE)
Memory location: 00, Reset state: 00xx 0xxx
Figure 19. Status/Control Register
B7(MSB)
B6
B5
B4
B3
B2
0
0
X
X
0
X
R/W
R/W
R
R
R/W
R
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
www.ti.com
B1
B0(LSB)
X
X
R
R
BIT
B7(MSB)
FIELD (1) (2)
TMR_RST
B6
EN_BOOST
B5
STAT_1
B4
STAT_0
B3
EN_SHIPMODE
B2
B1
B0(LSB)
FAULT_2
FAULT_1
FAULT_0
Table 2. Status/Control Register Field Descriptions
TYPE
R/W
R/W
R
R
R/W
R
R
R
DESCRIPTION
Write: TMR_RST function, write 1 to reset the watchdog timer (auto clear)
Read: Always 0
(bq24260/1/1M only)
0-Charger Mode
1-Boost Mode (default 0)
00-Ready
01-Charge in progress
10-Charge done
11-Fault
0-Normal Operation
1-Ship Mode Enabled (default 0)
000-Normal
001-VIN > VOVP or Boost Mode OVP
010- Low Supply connected (VIN<VUVLO or VIN<VSLP) or Boost Mode Overcurrent
011- Thermal Shutdown
100-Battery Temperature Fault
101- Timer Fault (watchdog or safety timer)
110-Battery OVP
111-No Battery connected
(1) STAT_x bits show current status. These bits change based on the current condition. When a status change occurs, a single 128-µs
pulse on the STAT and INT outputs occur and the STATx and FAULT_x bits of the status registers are updated in the I2C. Once the
fault is removed, the STATx bits are updated to show the current status.
(2) FAULT_x bits show faults. If a fault occurs, these bits announce the fault and do not clear until read. If more than one fault occurs only
the highest priority fault is shown, ranked from 1 to 8 in the order shown in the table. When a fault occurs, a single 128-µs pulse on the
STAT and INT outputs occur and the STATx and FAULT_x bits of the status registers are updated in the I2C. The FAULT_x bits are not
cleared until they are read in the I2C and the fault condition no longer exists.
EN_BOOST Bit (Operation Mode)
The EN_BOOST bit selects the operation mode for the bq24260/1/1M/2. Write a 1 to enable boost mode
and regulate IN to 5V to supply OTG peripherals. See Boost Mode Operation for more details.
EN_SHIPMODE Bit
Writing the EN_SHIPMODE bit to a 1 latches off the IC, battery FET and BGATE until a high to low
transition on UVLO occurs. This means that if EN_SHIPMODE is written to a 1 while the input is
connected, it must first be removed and then replaced before the battery FET turns on. This allows the
end product with no load on the battery and the end user will enable the device by plugging it into the
adapter. The EN_SHIPMODE bit can be cleared using the I2C interface as well.
30
Submit Documentation Feedback
Copyright © 2013–2015, Texas Instruments Incorporated
Product Folder Links: bq24260 bq24261 bq24261M bq24262