DDC101 Datasheet, PDF (25/29 Pages) Burr-Brown (TI) – 20-BIT ANALOG-TO-DIGITAL CONVERTER
Aquisition
Time, K
X
N
Oversampled
Initial Data Point
Time
Clock
Cycles
M
Tracking Interval
Final Data
Point Start
M
Digital
Output
Measurement Time
DDC101 digital output is precise integration of input during measurement time.
FIGURE 25. DDC101 Equivalent Integrator Output for Single Integration with CDS.
Oversampled
X
Final Data Point
FUNCTION
USER SETTING
(Clock Cycles)
MEASUREMENT
TIME
(Calculated)
Integration Time (TINT)
Acquisition Time K
(TACQ)
16
Initial Data Point
Samples, M
128
Measurement Time
Final Data Point
Samples, M
128
1ms
8µs
64µs
64µs
928µs
TABLE XVI. Measurement Time with CDS.
FUNCTION
USER SETTING
(Clock Cycles)
MEASUREMENT
TIME
(Calculated)
Integration Time (TINT)
Acquisition Time, K
(TACQ) “No CDS”
Initial Data Point
Samples
Measurement Time
Final Data Point
Samples, M
1
None
128
1ms
0.5µs
0µs
64µs
967.5µs
TABLE XVII. Measurement Time without CDS.
below: one with Correlated Double Sampling (CDS) and the
other without CDS. Each example assumes that the recom-
mended system clock frequency of 2MHz is used and that
the time between “Final Data point Start” commands, (the
integration time, TINT) is 1ms.
Example with CDS. The Measurement Time with CDS is
calculated as the Integration Time (TINT) of 1ms less TACQ
and TOS. TOS, the oversampling time, is 1/2 of the Initial Data
Point time plus 1/2 the Final Data Point time since each
group of samples is averaged with the result at the midpoint
of each sample group.
Therefore, the Measurement Time = 1ms –(8 + 32 + 32)µs
= 928µs.
Example without CDS. The Measurement Time without
CDS is calculated as the Total Integration Time (TINT) of
1ms less TACQ and TOS. TOS, the oversampling time, is 1/2 of
the Final Data Point time since this group of samples is
averaged with the result at the midpoint of the sample group.
Therefore, the Measurement Time = 1ms –(0.5 + 32)µs
= 967.5µs.
Input Current Calculation
The following formula calculates the input current from the
actual DDC output:
With CDS:
i
=
500 pC
•
 DDC output
 220


T MEAS
i=
500
pC
•


DDC output
2 20


TINT – K clock periods – M clock periods
Without CDS:
i
=
500 pC
•
 DDC output
 220


T MEAS
i=
500
pC
•


DDC output
2 20


TINT – K clock periods – M / 2 clock periods
®
25
DDC101