PRINCIPLES OF OPERATION
line control register (LCR)
The format of the data character is controlled by the LCR. The LCR can be read. Its contents are described in
the following bulleted list and shown in Figure 19.
D Bits 0 and 1: LCR0 and LCR1 are the word length select bits. The number of bits in each serial character
is programmed as shown.
D Bit 2: LCR2 is the stop bit select bit. LCR2 specifies the number of stop bits in each transmitted character.
The receiver always checks for one stop bit.
D Bit 3: LCR3 is the parity enable bit. When LCR3 is set, a parity bit between the last data word bit and stop
bit is generated and checked.
D Bit 4: LCR4 is the even parity select bit. When LCR4 is set, even parity is enabled.
D Bit 5: LCR5 is the stick parity bit. When parity is enabled (LCR3 = 1), LCR5 = 1 causes the transmission
and reception of a parity bit to be in the opposite state from the value of LCR4. This forces parity to a known
state and allows the receiver to check the parity bit in a known state.
D Bit 6: LCR6 is the break control bit. When LCR6 is set, the serial output (SOUT1/SOUT0) is forced to the
spacing state (low). The break control bit acts only on the serial output and does not affect the transmitter
logic. When the following sequence is used, no invalid characters are transmitted because of the break:
Step 1: Load a zero byte in response to the transmitter holding register empty (THRE) status indicator.
Step 2: Set the break in response to the next THRE status indicator.
Step 3: Wait for the transmitter to be idle when transmitter empty status signal is set high (TEMT = 1); then
clear the break when the normal transmission has to be restored.
D Bit 7: LCR7 is the divisor latch access bit (DLAB) bit. LCR7 must be set to access the divisor latches DLL
and DLM of the baud rate generator during a read or write operation. LCR7 must be cleared to access the
receiver buffer register, the transmitter holding register, or the interrupt enable register.