English
Language : 

TLC3544_07 Datasheet, PDF (19/42 Pages) Texas Instruments – 5-V ANALOG, 3-/5-V DIGITAL, 14-BIT, 200-KSPS, 4-/8-CHANNELS SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH 0-5 V (PSEUDODIFFERENTIAL) INPUTS
TLC3544, TLC3548
5-V ANALOG, 3-/5-V DIGITAL, 14-BIT, 200-KSPS, 4-/8-CHANNELS SERIAL
ANALOG-TO-DIGITAL CONVERTERS WITH 0-5 V (PSEUDODIFFERENTIAL) INPUTS
SLAS266C – OCTOBER 2000 – REVISED MAY 2003
detailed description (continued)
Table 2. Configuration Register (CFR) Bit Definition
SDI BIT
D11
D10
D9
D8
D7
D[6:5]
D[4:3]
D2
D[1:0]
DEFINITION
Reference select:
0: Internal (4 V)
1: External
Conversion output code format select:
0: USB (unipolar straight binary)
1: Binary 2s complement
Sample period select for normal sampling
0: Long sampling (4X) 44 SCLKs
Don’t care in extended sampling.
1: Short sampling (1X) 12 SCLKs
Conversion clock source select:
0: Conversion clock = Internal OSC
1: Conversion clock = SCLK/4
Input mode select:
0: Single-ended
1: Pseudodifferential. Pin configuration shown below.
Pin Configuration of TLC3548
Pin Configuration of TLC3544
Pin No.
Single-ended Pseudodifferential polarity
Pin No.
Single-ended Pseudodifferential polarity
9
A0
10
A1
PLUS
MINUS
Pair A
9
A0
10
A1
PLUS
MINUS
Pair A
11
A2
12
A3
PLUS
MINUS
Pair B
11
A2
12
A3
PLUS
MINUS
Pair B
13
A4
14
A5
PLUS
MINUS
Pair C
15
A6
16
A7
PLUS
MINUS
Pair D
Conversion mode select:
00: One shot mode
01: Repeat mode
10: Sweep mode
11: Repeat sweep mode
Sweep auto sequence select (Note: These bits only take effect in conversion mode 10 and 11.)
TLC3548
TLC3544
Single ended(by ch)
Pseudodifferential (by pair) Single ended (by ch)
Pseudodifferential (by pair)
00: 0–1–2–3–4–5–6–7
01: 0–2–4–6–0–2–4–6
10: 0–0–2–2–4–4–6–6
11: 0–2–0–2–0–2–0–2
00: N/A
01: A–B–C–D–A–B–C–D
10: A–A–B–B–C–C–D–D
11: A–B–A–B–A–B–A–B
00: 0–1–2–3–0–1–2–3
01: 0–2–0–2–0–2–0–2
10: 0–0–1–1–2–2–3–3
11: 0–0–0–0–2–2–2–2
00: N/A
01: A–B–A–B–A–B–A–B
10: N/A
11: A–A–A–A–B–B–B–B
EOC/INT pin function select:
0: Pin used as INT
1: Pin used as EOC ( for mode 00 only)
FIFO trigger level (sweep sequence length). Don’t care in one shot mode.
00: Full (INT generated after FIFO level 7 filled)
01: 3/4 (INT generated after FIFO level 5 filled)
10: 1/2 (INT generated after FIFO level 3 filled)
11: 1/4 (INT generated after FIFO level 1 filled)
sampling period
The sampling period follows the command period. The selected signal is sampled during this time. The device
has three different sampling modes: normal short mode, normal long mode, and extended mode.
Normal Short Sampling Mode: Sampling time is controlled by SCLK. It takes 12 SCLK periods. At the end of
sampling, the converter automatically starts the conversion period. After configuration, normal sampling, except
FIFO READ and WRITE CFR commands, starts automatically after the fourth falling edge of SCLK that follows
the falling edge of CS if CS triggers the operation, or follows the rising edge of FS if FS initiates the operation.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265