English
Language : 

TLK4015 Datasheet, PDF (15/24 Pages) Texas Instruments – QUAD 0.6 TO 1.5 Gbps TRANSCEIVER
TLK4015
QUAD 0.6 to 1.5 Gbps TRANSCEIVER
SLLS541 – DECEMBER 2002
detailed description (continued)
built-in self-test (BIST)
The TLK4015 has a BIST function. By combining PRBS with loopback, an effective self-test of all the circuitry
running at full speed can be realized. The successful completion of the BIST is reported on the
Rx_ER/PRBS_PASSx terminal.
power-on reset
Upon application of minimum valid power, the TLK4015 generates a power-on reset. During the power-on reset
the RDx, Rx_ER, and Rx_DV/LOSx signal terminals to go to a high-impedance state. The Rx_CLK is held low.
The length of the power-on reset cycle is dependent upon the GTx_CLK frequency, but is less than 1 ms.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 to 3 V
Voltage range at TDx, ENABLEx, GTx_CLK, Tx_EN, Tx_ER, LOOPENx, PRBSENx . . . . . . . . . . . . –0.3 to 4 V
Voltage range at any other terminal except above . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 to VDD + 0.3 V
Storage temperature, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
Electrostatic discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HBM: 2 kV, CDM: 500 V
Characterized free-air operating temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 85°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential I/O bus voltages, are with respect to network ground.
AIR FLOW
θJA (C/W)
0.0 m/s
18.40
DISSIPATION RATING TABLE
0.5 m/s
1.0 m/s
16.92
15.95
2.5 m/s
14.70
electrical characteristics over recommended operating conditions (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VDD
ICC
Supply voltage
Supply current
PD
Power dissipation
Shutdown current
PLL start-up lock time
Data acquisition time
VDD = 2.5 V, freq = 0.6 Gbps, PRBS pattern
VDD = 2.5 V, Freq = 1.5 Gbps, PRBS pattern
VDD = 2.5 V, freq = 0.6 Gbps, PRBS pattern
VDD = 2.5V, freq = 1.5 Gbps, PRBS pattern
VDD = MAX, freq = 1.5 Gbps, worst case pattern †
Enable = 0, VDDA + VDD terminals = max
VDD, VDDA = MIN, EN ↑ to PLL acquire
TA
Operating free-air temperature
† Worst case pattern is a pattern that creates a maximum transition density on the serial transceiver
MIN
2.375
–40
TYP
2.5
290
580
725
1.45
8
0.1
1024
MAX
2.625
1.9
0.4
85
UNIT
V
mA
mA
mW
W
W
mA
ms
bits
°C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265