The pin PULSE_INIT determines the logic level applied to the pulse pins on power-up, i.e. with PULSE_INIT low, the pulse
pins will be initialized to low (default = 1).
The pulse width PW is controlled with the PULSEWIDTH register for the PULSER and PULSEW output pins per the following
formula:
PW
=
2 ⋅ PULSEWIDTH + 1
2520.6
The PULSE3 and PULSE4 output pins will always generate pulses with 50% duty cycle.
Internal Data (Directly by CE)
Accumulation Interval
CE Operations
Accumulation 1
XFER
Post Processing
Post 0
READY
Accumulation 2
XFER
Post 1
READY
Accumulation 3
XFER
Post 2
READY
Pulse Generator
Pulse 0
Pulse 1
Pulse 2
Post-Processed Data
CE Operations
Post Processing
Accumulation Interval
Accumulation 1
XFER
Post 0
READY
Pulse Generator
APULSE write
Pulse -1
Accumulation 2
XFER
Post 1
READY
APULSE write
Pulse 0
Accumulation 3
XFER
Post 2
READY
APULSE write
Pulse 1
External (Host data is transferred to the pulse generator in the first accumulation interval after the
next READY)
Accumulation Interval
CE Operations
Accumulation 1
Accumulation 2
Accumulation 3
XFER
XFER
XFER
Post Processing
Post 0
Post 1
Post 2
READY
READY
READY
Host Processing
Host 0
APULSE write
Host 1
APULSE write
Host 2
APULSE write
Pulse Generator
Pulse -2
Pulse -1
Pulse 0
Figure 8: Pulse Generator Timing