SM59D03G2 Datasheet, PDF (56/67 Pages) SyncMOS Technologies,Inc – 8-Bits Micro-controller
12.1.3 EEI flag register
SM59D03G2
8-Bits Micro-controller
8KB+ ISP Flash & 1KB RAM embedded
Mnemonic: KBF
7
6
KBF7 KBF6
R
R
5
KBF5
R
4
KBF4
R
3
KBF3
R
2
KBF2
R
1
KBF1
R
Address: FFh
0 Reset
KBF0 00h
R
KBF7: EEI line 7 flag
Set by hardware when the port line 7 detects a programmed level. It generates a EEI
interrupt request if the KBE.7 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF6: EEI line 6 flag
Set by hardware when the port line 6 detects a programmed level. It generates a EEI
interrupt request if the KBE.6 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF5: EEI line 5 flag
Set by hardware when the port line 5 detects a programmed level. It generates a EEI
interrupt request if the KBE.5 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF4: EEI line 4 flag
Set by hardware when the port line 4 detects a programmed level. It generates a EEI
interrupt request if the KBE.4 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF3: EEI line 3 flag
Set by hardware when the port line 3 detects a programmed level. It generates a EEI
interrupt request if the KBE.3 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF2: EEI line 2 flag
Set by hardware when the port line 2 detects a programmed level. It generates a EEI
interrupt request if the KBE.2 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF1: EEI line 1 flag
Set by hardware when the port line 1 detects a programmed level. It generates a EEI
interrupt request if the KBE.1 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
KBF0: EEI line 0 flag
Set by hardware when the port line 0 detects a programmed level. It generates a EEI
interrupt request if the KBE.0 bit in KBE register is set.
This register is read only access; the flag is automatically cleared by reading the register.
Specifications subject to change without notice contact your sales representatives for the most recent information.
ISSFD-M030