English
Language : 

S-807 Datasheet, PDF (35/42 Pages) Seiko Instruments Inc – HIGH-PRECISION VOLTAGE DETECTOR
HIGH-PRECISION VOLTAGE DETECTOR
S-807 Series
4. Output transistor current (IOUT)
4.1 Nch transistor current
(i) VDS-IOUT
(ii) VDD-IOUT
40
32
IOUT 24
(mA)
16
8
0
8.0
VDD=4.8 V
VDD=3.6 V
6.4
IOUT
(mA)
4.8
3.2
VDD=2.4 V
1.6
VDD=1.2 V
0
1.0 2.0 3.0 4.0 5.0
VDS (V)
Ta=-30°C
Ta=25°C
Ta=80°C
VDS=0.5 V
1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0
VDD (V)
4.2 Pch transistor current
VDS-IOUT
4.0
3.2
IOUT 2.4
(mA)
1.6
0.8
0
VDD=4.8 V
VDD=3.6 V
VDD=2.4 V
VDD=1.2 V
1.0 2.0 3.0 4.0 5.0
VDS (V)
5. Minimum operating voltage
5.1 CMOS active low output
5.2 CMOS active high output
4.0
3.2
VOUT 2.4
(V)
1.6
0.8
0
0.8 1.6 2.4 3.2 4.0
VDD (V)
5.0
4.0
VOUT 3.0
(V)
2.0
1.0
0
1.0 2.0 3.0 4.0 5.0
VDD (V)
34
Seiko Instruments Inc.