31. S-80740AH/AH-B4-X (Detection voltage : 3.904 to 4.096 V)
Parameter
Symbol
Conditions
Detection voltage
Hysteresis width
-VDET
VHYS
Current consumption ISS
Operating voltage
VDD
Output current
IOUT
Temperature
characteristic of -
VDET
∆-VDET
∆Ta
VDD = 6.0 V
Pch
VDS = 0.5 V
VDD = 1.2 V
VDD = 2.4 V
Nch
VDS = 0.5 V
VDD = 6.0 V
Ta=-30°C to 80°C
(Unless otherwise specified : Ta=25°C)
Min. Typ. Max. Unit Test
circuit
3.904 4.000 4.096
V
1
-VDET
-VDET
-VDET
V
1
×0.02 ×0.05 ×0.08

1.0
3.0
µA
2
1.0

15.0
V
1
0.03 0.09

mA
4
0.15 0.30

4.73 9.60

3

±0.5
 mV/°C 
32. S-80741AL/AL-A5-X, S-80741AN/AN-D5-X (Detection voltage : 4.001 to 4.199 V)
Parameter
Symbol
Conditions
Detection voltage
Hysteresis width
-VDET
VHYS
Current consumption ISS
Operating voltage
VDD
Output current
IOUT
Temperature
characteristic of -
VDET
∆-VDET
∆Ta
VDD = 6.0 V
Nch
VDS = 0.5 V
VDD = 1.2 V
VDD = 2.4 V
VDD = 3.6 V
Pch (CMOS VDD = 6.0 V
output)
VDS = 0.5 V
Ta=-30°C to 80°C
(Unless otherwise specified : Ta=25°C)
Min. Typ. Max. Unit Test
circuit
4.001 4.100 4.199
V
1
-VDET
-VDET
-VDET
V
1
×0.02 ×0.05 ×0.08

1.0
3.0
µA
2
1.0

15.0
V
1
0.23 0.50

mA
3
1.60 3.70

3.18 7.00

0.46 0.75

4

±0.51
 mV/°C 
33. S-80742AL/AL-A6-X, S-80742AN/AN-D6-X
S-80742SL-A6-X, S-80742SN-D6-X (Detection voltage : 4.099 to 4.301 V)
Parameter
Symbol
Conditions
Detection voltage
Hysteresis width
-VDET
VHYS
Current consumption ISS
Operating voltage
VDD
Output current
IOUT
Temperature
characteristic of -
VDET
∆-VDET
∆Ta
VDD = 6.0 V
Nch
VDS = 0.5 V
VDD = 1.2 V
VDD = 2.4 V
VDD = 3.6 V
Pch (CMOS VDD = 6.0 V
output)
VDS = 0.5 V
Ta=-30°C to 80°C
(Unless otherwise specified : Ta=25°C)
Min. Typ. Max. Unit Test
circuit
4.099 4.200 4.301
V
1
-VDET
-VDET
-VDET
V
1
×0.02 ×0.05 ×0.08

1.0
3.0
µA
2
1.0

15.0
V
1
0.23 0.50

mA
3
1.60 3.70

3.18 7.00

0.46 0.75

4

±0.53
 mV/°C 
Seiko Instruments Inc.