English
Language : 

C501_1 Datasheet, PDF (104/121 Pages) Siemens Semiconductor Group – 8-Bit Single-Chip Microcontroller
Device Specifications
C501
10.5 AC Characteristics for C501-L24 / C501-1R24 / C501-1E24
VCC = 5 V + 10 %, – 15 %; VSS = 0 V TA = 0 °C to 70 °C for the SAB-C501
TA = – 40 °C to 85 °C for the SAF-C501
(CL for port 0, ALE and PSEN outputs = 100 pF; CL for all other outputs = 80 pF)
Program Memory Characteristics
Parameter
ALE pulse width
Address setup to ALE
Address hold after ALE
ALE low to valid instr in
ALE to PSEN
PSEN pulse width
PSEN to valid instr in
Input instruction hold after PSEN
Input instruction float after PSEN
Address valid after PSEN
Address to valid instr in
Address float to PSEN
Symbol
Limit Values
Unit
24 MHz
Clock
min. max.
Variable Clock
1/tCLCL = 3.5 MHz to 24 MHz
min.
max.
tLHLL
43 –
2tCLCL – 40
–
ns
tAVLL
17 –
tCLCL – 25
–
ns
tLLAX
17 –
tCLCL – 25
–
ns
tLLIV
–
80 –
4tCLCL – 87
ns
tLLPL
22 –
tCLCL – 20
–
ns
tPLPH
95 –
3tCLCL – 30
–
ns
tPLIV
–
60 –
3tCLCL – 65
ns
tPXIX
0
–
0
–
ns
t *)
PXIZ
–
32 –
tCLCL – 10
ns
t *)
PXAV
37
–
tCLCL – 5
–
ns
tAVIV
–
148 –
5tCLCL – 60
ns
tAZPL
0
–
0
–
ns
*) Interfacing the C501 to devices with float times up to 37 ns is permissible. This limited bus contention will not
cause any damage to port 0 Drivers.
Semiconductor Group
10-7