English
Language : 

GS2962 Datasheet, PDF (67/82 Pages) Gennum Corporation – Integrated Narrow-Bandwidth PLL
Table 4-16: Configuration and Status Registers (Continued)
Address Register Name Bit Name
001h
ERROR_STAT
RSVD
TRS_PERR
Y1_EDH_CS_ERR
Y1_CS_ERR
FORMAT_ERR
TIMING_ERR
NO_352M_ERR
LOCK_ERR
Bit
15-7
6
5
4
3
2
1
0
Description
Reserved.
TRS protection error.
LOW - No errors in TRS.
HIGH - Errors in TRS.
Same as CS_ERR but only updates
its state when packet being
inspected is an EDH packet.
HIGH indicates that a checksum
error is detected. It is updated
every time a CS word is present on
the output.
NOTE: This bit will not be set for
CSUM values in the protected
ranges (from 000h to 003h and
from 3FCh to 3FFh).
HIGH indicates standard is not
recognized for 861D conversion.
HIGH indicates that the RASTER
measurements do not line up with
the extracted 352M packet
information.
HIGH indicates no 352M packet
embedded in incoming video.
HIGH indicates PLL lock error
indication.
R/W
R
R
R
R
R
R
R
R
Default
0
0
0
0
0
0
0
0
GS2962 3G/HD/SD-SDI Serializer with Complete
SMPTE Video Support
Data Sheet
48005 - 7
October 2010
67 of 82