English
Language : 

BU9414FV Datasheet, PDF (19/61 Pages) Rohm – 32bit Audio DSP
BU9414FV
Explanation of A_RATE_Low,R_RATE_Low(field transition of (1)<->(2))
VImin
Input VI
Tme T
Field (1)
VOmin
Output VO
Field (2)
Field (1)
Time T
Technical Note
Recovery operation
R_RATE_Low
The time from falling
below the recovery
operation detection level
oVpIemraitnion'tsill
the recovery
transition to
Field (2) is completed
Attack operation
A_RATE_Low
The time from exceeding
the attack operation
adtettaeccktioonpelreavteiol nV'sImtirnantisllittiohen
to Field (1) is completed
Setting 2 of the transition time at the time of attack
A_RATE_LOW is the setting of transition time when the state of P2Volume function is transited to (2)→(1).
Default = 0
Select Address
Operational explanation
&h3A [ 6:4 ]
Command A_RATE_LOW Time Command A_RATE_LOW Time
0
1ms
4
5ms
1
2ms
5
10ms
2
3ms
6
20ms
3
4ms
7
40ms
Setting 2 of the transition time at the time of recovery
R_RATE_LOW is the setting of transition time when the state of P2Volume function is transited to (1)→(2).
Default = 0
Select Address
Operational explanation
&h3A [ 2:0 ]
Command R_RATE_LOW Time Command R_RATE_LOW Time
0
1ms
4
5ms
1
2ms
5
10ms
2
3ms
6
20ms
3
4ms
7
40ms
Setting 2 of attack recovery detection time
A_TIME_LOW is the setting of the initiation of P2Volume function’s transition operation. If the input level below A continues more than
continuation A_TIME_LOW in the state of (2) or (3), state transition of P2Volume will be started toward the state of (1).
Default = 0
Select Address
Operational explanation
&h3B [ 6:4 ]
Command
0
1
2
3
A_TIME_LOW
50ms
100ms
150ms
200ms
Command
4
5
6
7
A_TIME_LOW
300ms
400ms
500ms
600ms
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
19/57
2012.03 - Rev.A