English
Language : 

QT40.361 Datasheet, PDF (8/27 Pages) PULS GmbH – THREE PHASE INPUT
Q-Series
QT40.361
36V, 26.7A, THREE PHASE INPUT
7. HOLD-UP TIME
3AC 400V*) 3AC 480V*)
Hold-up Time
typ.
50ms
50ms
at 36V, 13.3A, see Fig. 7-1
min.
40ms
40ms
at 36V, 13.3A, see Fig. 7-1
typ.
25ms
25ms
at 36V, 26.7A, see Fig. 7-1
min.
20ms
20ms
at 36V, 26.7A, see Fig. 7-1
*) Curves and figures for operation on only 2 legs of a 3-phase system can be found in chapter 24.4
Fig. 7-1 Hold-up time vs. input voltage
Hold-up Time
50ms
40
36V, 13.3A, typ.
36V, 13.3A, min.
30
20
10
0
320
36V, 26.7A, typ.
36V, 26.7A, min.
Input Voltage
360 400 440 3x480Vac
Fig. 7-2 Shut-down behavior, definitions
L1 L2 L3
Input
Voltage
Output
Voltage
Hold-up Time
- 5%
Dec. 2016 / Rev. 1.3 DS-QT40.361-EN
All parameters are specified at 36V, 26.7A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
8/27