QT40.361 Datasheet, PDF (6/27 Pages) PULS GmbH – THREE PHASE INPUT
Q-Series
QT40.361
36V, 26.7A, THREE PHASE INPUT
6. OUTPUT
Output voltage
Adjustment range
Factory setting
Line regulation
Load regulation
Ripple and noise voltage
Output current
Output power
BonusPower® time
BonusPower® recovery time
Overload behavior
Short-circuit current**)
Output capacitance
nom.
min.
max.
typ.
typ.
typ.
max.
max.
typ.
36V
36-42V
45V***)
36.0V
36.0V
37.5V
10mV
50mV
1500mV
max.
nom.
nom.
nom.
130mVpp
26.7A
22.9A
40A
nom. 34.3A
typ. 73A
nom.
nom.
typ.
typ.
min.
max.
min.
max.
typ.
max.
typ.
960W
1440W*)
4s
7s
cont. current
27A
30A
40A
45A
33A
37A
4 700μF
guaranteed
at clockwise end position of potentiometer
±0.2%, at full load, cold unit, in “single use” mode
±0.2%, at full load, cold unit, in “parallel use” mode
at no load, cold unit, in “parallel use” mode
3x323-576Vac
in “single use” mode: static value, 0AÆ26A, see Fig. 6-1
in “parallel use” mode: static value, 0AÆ26A,
see Fig. 6-2
20Hz to 20MHz, 50Ohm
continuously available at 36V, see Fig. 6-1 and Fig. 6-2
continuously available at 42V, see Fig. 6-1 and Fig. 6-2
short term (4s) available BonusPower®*), at 36V,
see Fig. 6-1, Fig. 6-2 and Fig. 6-4
short term (4s) available BonusPower®*), at 42V,
see Fig. 6-1, Fig. 6-2 and Fig. 6-4
up to 25ms, output voltage stays above 30V, see Fig.
6-4, This peak current is available once every second.
See chapter 24.2 for more peak current measurements.
continuously available at 36-42V
short term available BonusPower®*) at 36-42V
duration until the output voltage dips, see Fig. 6-3
overload free time to reset power manager, see Fig. 6-5
see Fig. 6-1
continuous, load impedance 40mOhm, see Fig. 6-1
continuous, load impedance 40mOhm, see Fig. 6-1
short-term (4s), load impedance 40mOhm, see Fig. 6-1
short-term (4s), load impedance 40mOhm, see Fig. 6-1
continuous, load impedance <10mOhm
continuous, load impedance <10mOhm
included in the power supply
*)
**)
***)
BonusPower®, short term power capability (up to typ. 4s)
The power supply is designed to support loads with a higher short-term power requirement without damage or shutdown. The short-
term duration is hardware controlled by an output power manager. This BonusPower® is repeatedly available. Detailed information
can be found in chapter 24.1. If the power supply is loaded longer with the BonusPower® than shown in the bonus-time diagram (see
Fig. 6-3), the max. output power is automatically reduced to 960W.
Discharge current of output capacitors is not included.
This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not
guaranteed value which can be achieved. The typical value is about 42.5V.
Dec. 2016 / Rev. 1.3 DS-QT40.361-EN
All parameters are specified at 36V, 26.7A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.