QT40.361 Datasheet, PDF (10/27 Pages) PULS GmbH – THREE PHASE INPUT
Q-Series
QT40.361
36V, 26.7A, THREE PHASE INPUT
10. REMOTE CONTROL OF OUTPUT VOLTAGE
The shut-down input can also be used to remotely adjust the output voltage between typically 33Vdc and 42Vdc. All
other functions of shut-down input remain the same.
The control voltage is referenced to the main ground (negative output voltage)
Fig. 10-1 Remote control of the output
voltage
Fig. 10-2 Applying the control voltage
Output Voltage
42V
39V
Potentiometer:
42V setting
36V setting
36V
33V
30V
27V
24V
21V
18V
0V
5V
10V
Control Voltage
Control
Voltage
min. 0V
max. +50V
15 Shut-
down
+
16 Input
n.c.
-
Instructions:
1. Set the unit into “Single Use” mode
2. Set the output voltage adjustment (36-42V) to the maximum desired voltage.
3. Apply a control voltage to reduce the output voltage
Dec. 2016 / Rev. 1.3 DS-QT40.361-EN
All parameters are specified at 36V, 26.7A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
10/27