Table 20. STATUS REGISTER 1 PARAMETERS
Parameter
Value
Value
Description
Info
0
No overcurrent
OVCXPT
Overcurrent detection in top transistor XP−terminal
p23
1
Overcurrent
0
No overcurrent
OVCXPB
1
Overcurrent detection in bottom transistor XP−terminal
p23
Overcurrent
0
No overcurrent
OVCXNT
Overcurrent detection in top transistor XN−terminal
p23
1
Overcurrent
0
No overcurrent
OVCXNB
1
Overcurrent detection in bottom transistor XN−terminal
p23
Overcurrent
0
No charge pump failure
CPFAIL
Charge pump failure detection
p23
1
Charge pump failure
OPEN_X
0
No open coil detected
Open coil detection for X−coil
1
Open coil detected
Note: a short circuit could trigger an open coil
p23
Status Register 2 (SR2)
Status Register 2 is located at address 0x06 and can only be read. Status Register 2 is a latched register. If an error occurs
the bit will be set and can only be cleared by reading out this bit2. The register is used to report an overcurrent or open coil in
the Y−coil, or to report a thermal shutdown.
Notice that bit 7 is the parity bit (see READ operation p26).
Table 21. STATUS REGISTER 2
Address
0x06
Access
Reset
Data
Bit 7
R
0
PAR
Status Register 2 (SR2)
Bit 6
Bit 5
Bit 4
R
R
R
0
0
0
OVCYPT OVCYPB OVCYNT
Bit 3
R
0
OVCYNB
Bit 2
R
0
TSD
Bit 1
R
0
OPEN_Y
Bit 0
R
0
−
Table 22. STATUS REGISTER 2 PARAMETERS
Parameter
Value
Value
Description
Info
0
No overcurrent
OVCYPT
Overcurrent detection in top transistor YP−terminal
p23
1
Overcurrent
0
No overcurrent
OVCYPB
1
Overcurrent detection in bottom transistor YP−terminal
p23
Overcurrent
0
No overcurrent
OVCYNT
Overcurrent detection in top transistor YN−terminal
p23
1
Overcurrent
0
No overcurrent
OVCYNB
1
Overcurrent detection in bottom transistor YN−terminal
p23
Overcurrent
0
No thermal shutdown
TSD
Thermal Shutdown detection
p23
1
Thermal shutdown
0
No open coil detected
Open coil detection for X−coil
OPEN_Y
1
Open coil detected
Note: a short circuit could trigger an open coil
p23
2. In Sleep mode the register can be read out but will not be cleared!