English
Language : 

E3X-DA11-N Datasheet, PDF (8/36 Pages) Omron Electronics LLC – The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance
E3X-DA-N
Digital Fiber Amplifiers with Differential Outputs (E3X-DA11D/E3X-DA6D)
Characteristics of Applicable Fiber Units
Through-beam Fiber Units
Sensing distance (mm) (The figures in parentheses apply when using the 39-F1 Lens Unit.)
Sensitivity selection
11-level setting
1
HIGH
2
3 to 11
1
LOW
2
3 to 11
Standard object
(mm) *1
(min. sensing
Fiber Unit
Response 270 or
time 570 μs
0.5 or 1 ms
1 to 200 ms
or
2 to 400 ms
270 or
570 μs
0.5 or 1 ms
1 to 200 ms
or
2 to 400 ms
object *2:
opaque)
E32-T11R
E32-T21R
240 (1680)
50
280 (1960)
60
370 (2590)
80
140 (980)
30
180 (1260)
40
240 (1680)
50
1 dia. (0.01 dia.)
E32-T16WR
580
690
910
350
450
580
(0.3 dia.) *1
E32-T16PR
380
450
600
230
290
380
(0.2 dia.) *2
*1. These values are for sensing objects that are moving.
*2. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating
temperature. (The value is for sensing objects that are moving.)
*3. The values given in the above table are those that can be detected at a digital value of 1,000 in each sensing area.
Reflective Fiber Units
Sensitivity selection
11-level setting
1
Fiber Unit
Response 270 or
time 570 μs
HIGH
2
0.5 or 1 ms
Sensing distance (mm) *1
3-11
1 to 200 ms
or
2 to 400 ms
1
270 or
570 μs
LOW
2
0.5 or 1 ms
3-11
1 to 200 ms
or
2 to 400 ms
Standard object
(mm) *2
(min. sensing
object *3:
opaque)
E32-D11R
150 × 150
80
90
120
45
60
80
(0.01 dia.)
E32-D21R
13
15
20
7
10
13
25 × 25 (0.01 dia.)
*1. Sensing distances are given for white paper.
*2. These values are for sensing objects that are moving.
*3. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating
temperature. (The value is for sensing objects that are moving.)
Differences Compared with E3X-DA-N Amplifier
Differential-output Models (Edge-detection Models)
Type
Pre-wired
Wire-saving connector
Item
NPN output
E3X-DA11D
E3X-DA6D
Current consumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Con-
Load current: 50 mA max., (Residual voltage: 1 V max. for NPN/PNP output)
trol
ON/OFF output Open collector
output
Switchable between Light ON (ON at edge detection) and Dark ON (OFF at edge detection)
Detection mode
Switchable between single edge and double edge detection mode
Response time
Single edge: Can be set to 270 μs, 500 μs, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, or 200 ms.
Double edge: Can be set to 570 μs, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms or 400 ms.
Timer functions
Light ON: OFF-delay timer, Dark ON: ON-delay timer
0 to 5 s (1 to 20 ms: 1-ms units, 20 to 200 ms: 5-ms units, 200 ms to 1 s: 100 ms, 1 to 5 s: 1-s units)
APC
Yes
Func- Zero-reset
tions Initial reset
Yes (Negative values can be displayed.)
Yes (Settings can be returned to defaults.)
Sensitivity se-
lection
Yes (HIGH/LOW)
Teaching level One-point teaching level can be varied from 1% to 50% in increments of 1%
Indicators
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital detection level display
(red)
For other information, refer to the instruction manual supplied with the product.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
8