Teaching (SET Mode)
• The four types of teaching given below are available.
• Once the setting is made, the Amplifier operates according to the settings. The red level display will flash if a teaching error
occurs. In that case, repeat the whole teaching procedure.
With twin-output models, switch to the channel to be adjusted using the channel-selection switch.
CH1
CH2
Set the mode selector to SET to start teaching.
Maximum Sensitivity Setting
Step
Operation
1 Set the mode selector to SET.
Press the TEACH button for at
2 least 3 seconds.
Setting is complete when the
level display changes from red to
3 green.
The level display will display the
digital incident level later.
4 Set to RUN mode.
SET
SET
TEACH
3s
(Red)
(Green)
RUN
Two-point With/Without-object Teaching
Step
Operation
1 Set the mode selector to SET.
SET
Press the TEACH button for
approximately 1 second when
2 the object is at the sensing
position.
3 The red level display is lit.
Object
TEACH
1s
(Red)
One-point Without-object Teaching
Step
Operation
1 Set the mode selector to SET.
SET
Press the TEACH button for
2 approximately 1 second.
Teaching is complete when the
red level display is lit. The level
3 display will display the digital
incident level later.
4 Set to RUN mode.
TEACH
1s
(Red)
RUN
Press the TEACH button for
4 approximately 1 second with no
object.
TEACH
1s
Teaching is complete when the green
5 level display is lit.The level display will
display the digital incident level later.
6 Set to RUN mode.
(Green)
RUN
Note: The order of “with-object” and “without-object” setting steps above can be
reversed.
Pin-point Teaching (for Positioning)
Step
Operation
1 Set the mode selector to SET.
SET
The threshold is automatically
5 set with the object.
Object
Out- ON
put
Note: If one-point teaching is not available because the difference in level is too
fine, try two-point teaching.
Operating Mode Selector
Operating mode
Operation
Light-ON
Dark-ON
L-ON
D-ON
L (Factory-set)
D
Note: There is no operating mode selector for twin-output models.
Press the TEACH button for
2 approximately 1 second with no
object.
3 The red level display is lit.
TEACH
1s
(Red)
Place the object in the desired
4 position, and press the TEACH
button for at least 3 seconds.
Teaching is complete when the green
level display is lit.
5
The level display will display the digital
incident level later. (The red level
display will flash if a teaching error
occurs.)
6 Set to RUN mode.
Object
TEACH
3s
(Green)
RUN