English
Language : 

E3X-DA11-N Datasheet, PDF (19/36 Pages) Omron Electronics LLC – The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance
Amplifier Adjustments
All Models
1 Changing the Display (RUN Mode)
Set the mode
selector to RUN.
RUN
(Factory-set to RUN)
Digital incident level (4000 max.)
MODE
2s
Digital percent
MODE
2s
Analog incident level and threshold
MODE
2s
Manual Tuning (Fine Sensitivity Adjustment) in ADJ Mode
Perform fine sensitivity adjustment after teaching and
manual tuning (without using the teaching function) in
the way shown below:
Twin-output Models
First, select the channel to be
adjusted using the channel
selection switch.
CH1
CH2
Set the mode
selector to ADJ.
Fine sensitivity adjustment
TEACH
MODE
ADJ
Sensitivity Sensitivity
increment with decrement
threshold with threshold
decrement increment
The items displayed in ADJ mode vary with the display
setting in RUN mode.
RUN mode
Digital incident level
Digital percent
Analog value
ADJ mode
Digital threshold
Digital percent
Analog value
E3X-DA-N
2 Zero-reset (RUN Mode)
Set the mode
selector to RUN.
RUN
Digital incident level (4000 max.)
TEACH
1s
*
To reset to zero again:
TEACH
1s
To return the initial digital incident level:
TEACH
MODE
Hold down
both for 3 s.
*There is no limit on the number of times zero-reset can be used.
3 Initial Reset (SET Mode)
Set the mode
selector to SET.
SET
TEACH
MODE
Hold down
both for 5 s.
TEACH
MODE
MODE
Cancel
Execute initial reset
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
19