English
Language : 

E3X-DA11-N Datasheet, PDF (16/36 Pages) Omron Electronics LLC – The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance
I/O Circuit Diagrams
E3X-DA-N
NPN Output
Model
Opera-
tion
mode
Timing charts
Mode selec-
tor switch
Output circuit
E3X-DA11-N
E3X-DAB11-N
E3X-DAG11-N
E3X-DAH11-N
E3X-DA11V
E3X-DA6
E3X-DAB6
E3X-DAG6
E3X-DAH6
E3X-DA14V
Light-ON
Dark-ON
Incident light
No incident light
Operation
ON
T
indicator
(orange)
OFF
Output
transistor
ON
OFF
Load
Operate
(e.g., relay) Reset
(Between brown and black)
Incident light
No incident light
Operation
indicator
ON
T
(orange)
OFF
Output
transistor
ON
OFF
Load
Operate
(e.g., relay) Reset
(Between brown and black)
L-ON
(LIGHT ON)
D-ON
(DARK ON)
Display
Operation indicator (orange)
Photo-
electric
Sensor
main
circuit
Brown
1
Black Load
4
Control output
Blue
3
12 to
24 VDC
• Connector Pin Arrangement
(M-8 Connector only)
Note: Pin 2 is not used.
24
1
3
E3X-DA21-N
E3X-DA7
Light-ON
Incident light
No incident light
Operation
ON
T
indicator
(orange)
OFF
Output
ON
transistor
OFF
Load
Operate
(e.g., relay) Reset
(Between brown and black)
L-ON
(LIGHT ON)
Dark-ON
Incident light
No incident light
Operation
indicator
ON
T
(orange)
OFF
Output
transistor
ON
OFF
Load
Operate
(e.g., relay) Reset
(Between brown and black)
D-ON
(DARK ON)
Display
Operation indicator (orange)
Photo-
electric
Sensor
main
circuit
47 Ω
* Load resistance: 10 kΩ min.
Brown
Black Load
Control output
Orange
Monitor
output
1 to 5 V
*
Load
Blue
12 to
24 VDC
E3X-DA11TW
E3X-DA6TW
Light-ON
CH1/ Incident light
CH2 No incident light
Operation
ON
T
indicator
(orange)
OFF
Output
ON
transistor
OFF
Load
Operate
(e.g., relay) Reset
(Between brown and black)
L-ON
(LIGHT ON)
Dark-ON
CH1/ Incident light
CH2 No incident light
Operation
ON
T
indicator
(orange)
OFF
Output
ON
transistor
OFF
Load
Operate
(e.g., relay) Reset
(Between brown and black)
D-ON
(DARK ON)
Operation
indicator
(orange)
Display
Operation indicator (orange)
Photo-
electric
Sensor
main
circuit
Note: With E3X-DA@TW models, only channel 1 is output when set for area sensing operation.
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. (Channel 2 is always OFF.)
Brown
Black Load
Control output 1 Load
Orange
Control output 2
12 to
24 VDC
Blue
Sensor I/O Connectors for Models with M8 Connectors
42
1
3
1
2
3
4
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Wire colors
Brown
White
Blue
Black
Classifi-
cation
DC
Wire colors
Brown
White
Blue
Black
Note: Pin 2 is not used.
Connection
pin No.
1
2
3
4
Application
Power supply (+V)
---
Power supply (0 V)
Output
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.