English
Language : 

E3X-DA11-N Datasheet, PDF (15/36 Pages) Omron Electronics LLC – The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance
Technical Reference (for E3X-DA-TW Twin-output Models)
E3X-DA-N
(In the following examples, threshold 1 is set
to 3,000, and threshold 2 is set to 1,000.)
Output Patterns for Normal Operation
Outputs 1 and 2 can be set to operate independently and either Light ON mode or
Dark ON mode can be selected (independently) for channels 1and 2 making a total
of 4 possible output patterns.
Threshold 1: Light ON
Threshold 2: Light ON
4000
3000
Threshold 1
Threshold 1: Dark ON
Threshold 2: Light ON
4000
3000
Threshold 1
1000
0
Threshold 2
Time
1000
0
Threshold 2
Time
ON
Output 1
OFF
ON
Output 2
OFF
Threshold 1: Light ON
Threshold 2: Dark ON
ON
Output 1
OFF
ON
Output 2
OFF
Threshold 1: Dark ON
Threshold 2: Dark ON
4000
3000
Threshold 1
4000
3000
Threshold 1
1000
0
ON
Output 1
OFF
ON
Output 2
OFF
Threshold 2
Time
1000
0
ON
Output 1
OFF
ON
Output 2
OFF
Threshold 2
Time
Output Patterns for Area Sensing
This series includes models equipped
with area sensing functionality, a first for
Digital Fiber Amplifiers. This
functionality can be used to monitor
whether the incident level is inside or
outside the threshold area. The 2 output
patterns below are possible for this kind
of operation.
ON inside threshold area
4000
3000
Threshold 1
1000
0
Threshold 2
Time
ON
Output 1
OFF
ON
Output 2
OFF
ON outside threshold area
4000
3000
Threshold 1
1000
0
ON
Output 1
OFF
ON
Output 2
OFF
Note: Output 2 is always OFF.
Threshold 2
Time
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
15