E3X-DA-N
Twin-output Models
4 Setting Functions (SET Mode)
Set mode selector to
SET.
SET
Digital incident level display
Teaching
Four types of sensitivity settings are available. Refer to page 22 for
details.
Setting the operating mode Changing the operating mode
The operating mode for the channel
set with the channel-selection switch
can be changed.
Changed using the channel-selection switch
CH1
CH2
Channel 1
Channel 2
L-ON
(Factory setting)
TEACH
L-ON
(Factory setting)
TEACH
D-ON
D-ON
MODE
2s
Sensing function Displayed as “F.”
B
A
Standard (factory-set)
TEACH
Super-long distance
TEACH
Super-high speed
TEACH
Area
TEACH
● Area Sensing
Area sensing is possible using the threshold values
for channels 1 and 2.
• If channel 1 is set to L-ON, output turns ON when
the incident level is between the thresholds.
• If channel 1 is set to D-ON, output turns OFF
when the incident level is between the
thresholds.
The result is output to control output 1.
(Control output 2 is always OFF.)
B
A
MODE
2s
Timer function Displayed as “t.”
MODE
2s
(Factory setting)
TEACH
200
TEACH
Adjustable in 1-ms units
for 0 to 20 ms and in 5-ms
units for 25 ms or higher.
Flashing setting Displayed as “L.”
MODE
2s
OFF (factory-set)
TEACH
ON
TEACH
Hold setting
Displayed as “H.”
MODE
2s
OFF (factory-set)
TEACH
Peak
TEACH
Bottom
TEACH
Display orientation setting Reversing display
Standard (factory-set)
TEACH
Reverse
TEACH
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.