E3X-DA-S Datasheet, PDF (8/28 Pages) Omron Electronics LLC – Digital Fiber Sensors | |||
|
◁ |
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) Â E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Detection without background interference (Convergent-reflective)
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
Size
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
Reflective
models
Flat view
Top view
Flat view
Standard
Small
---
E32-L16-N 2M â½
E32-L24S 2M â½
E32-L25L 2M â½
E32-L24L 2M â½
0 to 15
0 to 4
5.4 to 9 (center 7.2)
2 to 6 (center 4)
0 to 12
â½ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Detection of transparent objects (Retro-reflective)
Sensing distance (unit: mm)
Sensing
method
Type
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
Retrore-
flective
models
Square
Small
Film detection â½2
E32-R16 5M + E39-R1 (attached) â½1
E32-R21 2M + E39-R3 (attached) â½1
E32-C31 2M + E39-F3R+E39-RP37 â½1
E32-C31 2M + E39-F3R+E39-RSP1 â½1
150 to 1,500
10 to 250
250
450
200
---
300
100
â½1. When using a highly reflective object, light reflected from the object may affect the sensor.
â½2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens
Unit. Be sure to check operation in advance.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
FPD / Semiconductor / Solar battery industry
Sensing distance (unit: mm)
Sensing
method
Application
Operating
temperature
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
Glass detection
E32-L16-N 2M â½
0 to 15
0 to 12
Glass substrate
alignment
70°C
300°C
E32-L16-N 2M â½
E32-A08 2M â½
E32-A08H2 3M â½
0 to 15
10 to 20
10 to 20
0 to 12
---
---
Reflective
models Glass substrate
mapping
70°C
150°C
300°C
E32-A09 2M
E32-A09H 2M
E32-A09H2 2M
15 to 38
---
15 to 38
---
20 to 30
---
60°C
E32-L11FP 5M
8 to 20 mm from end of lens (recommended: 11 mm)
WET process
70°C
E32-L12FS 5M
8 to 20 mm from end of lens (recommended: 11 mm)
85°C
E32-L11FS 5M
8 to 20 mm from end of lens (recommended: 11 mm)
Through-
beam
Wafer mapping
models
70°C
E32-A03 2M
E32-A03-1 2M
E32-A04 2M
E32-A04-1 2M
3,220
2,300
1,780
1,200
500
3,220
2,300
1,780
1,200
500
1,280
920
680
450
200
1,280
920
680
450
200
â½ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Liquid-level detection model
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
Pipe diameter
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
No limit
E32-D36T 5M â½1, â½2
Applicable pipe: Transparent (no restriction on diameter)
Reflective Mounted to pipe
models
Ï8 to 10 mm
E32-L25T 2M
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,
recommended pipe wall thickness: 1 mm
Wet
---
E32-D82F1 4M â½1
Wet model
â½1. If a high level of light is received, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
â½2. In Tough mode, detection may not be possible depending on the pipe diameter. Check operation with the pipe that will be used.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).