5 Setting Functions (SET Mode)
Moving between Functions
➜Refer to 4. Teaching the
Threshold on page 15.
✽ The function transition boxes show the default settings.
✽ More functions may be displayed depending on the detailed settings.
Set the SET/RUN Mode
Selector Switch to SET.
SET
Teaching
0. Operation mode
(To set the operation mode)
1. Detection
(To change response speed and
detection precision)
2. Timer
(To use the timer setting)
3. Teaching level
(To change the teaching level)
11. External input memory
(Refer to the Instruction Manual
provided with the sensor.)
MODE
4. ATC setting
(To change the ATC setting)
10. External input
(To change functions controlled
using the external input)
9. Output setting
(To change outputs for
channel 2)
8. ECO Mode
(To set the ECO Mode)
7. Display orientation
(To reverse the orientation of
the display.)
6. Display switch
(To change the display method)
5. MODE Key
(To change the function of the
MODE Key during operation)
When the
settings have
been completed
Set the SET/RUN Mode
Selector Switch to RUN.
RUN
Functions
UP
DOWN
Use the UP and DOWN Keys to change the settings.
Function ✽
Setting (display)
0. Operation mode
Light ON: , Dark ON:
Description
➜Refer to 1. Setting the Operation Mode on page 14.
1. Detection ✽
Super-high-speed: , High-speed: , Standard:
,
High-resolution:
, Tough: , Differential operation:
Used to change the response speed or detection precision.
Differential edge
(differential operation Single edge:
selected)
, Double edge:
Used to set the edge to be detected.
Differential time
Single edge···250 µs: , 500 µs: , 1 ms: , 10 ms: , 100 ms: ,
Double edge···500 µs: , 1 ms: , 2 ms: , 20 ms: , 200 ms:
Used to set the differential response time.
2. Timer
Time
(timer enabled)
3. Teaching level
Timer disabled:
, OFF-delay timer:
,
ON-delay timer:
, One-shot timer:
ON-delay + OFF-delay timer:
Used to enable or disable timers.
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments, Used to change timer settings when timers are enabled.
200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments The timer can be set from 1 to 5,000 ms.
Setting range: to
Used to change the threshold setting when teaching a
Through-beam Fiber Unit without a workpiece or teaching
a Reflective Fiber Unit without a workpiece.
4. ATC setting
ATC enabled: , ATC disabled:
Used to enable or disable the ATC function.
Setting at Power-ON No setting: , ATC start processing: ,
(ATC ON)
Power tuning and ATC start processing:
Used to set the processing to be performed when the
power is turned ON.
5. MODE Key ✽
Executes power tuning:
,
Executes a zero reset:
, Two-point teaching:
Automatic teaching:
, ATC start:
Power tuning target value Setting range: 100 to 3,900 (increments of 100)
(performing power tuning) Maximum power :
Used to change the function of the MODE Key during RUN
, operation.
Used to set target values during power tuning.
➜Refer to 2. Adjusting the Power on page 14.
✽ The detection settings and MODE Key settings are the same for channel 1 and channel 2.
Other functions can be set separately for each channel.
16