English
Language : 

E3X-DA-S Datasheet, PDF (23/28 Pages) Omron Electronics LLC – Digital Fiber Sensors
Dimensions
Amplifier Units
Pre-wired Models
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA21F-S
E3X-DA51F-S
101.45
4.5
5.65
E3X-DA-S
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Digital Display Area
15.6
35.25
Indicator ✽1
10
6.3
Operation indicator (1ch)
Main display
Sub-display
✽1. The indicators are as follows:
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA21F-S
E3X-DA51F-S
Operation indicator
(2 ch)
APC alarm output
indicator
Power tuning
indicator
DIN track mounting
4.3
141.1
180°
32
(9)
3.4
Two, 2.4 dia.
18.7
(36.2)
70
Vinyl-insulated round cable
Standard length: 2 m ✽2
12.5
Hole for optical communications
(21.3)
Multiple connection diagram
End Plate
L
(sold separately)
PFP-M
10
101.45
Center of DIN track
DIN track
(sold separately)
PFP-@N
Fiber Attachment mounted (E39-F9)
With Mounting Bracket Attached
4.3
141.1
180°
10
10
The number of expansion
1
2
3
4
5
6
7
8
9
10
L (mm)
10
20
30
40
50
60
70
80
90
100
32
(9)
4.5
5.65
3.4
Two, 2.4 dia.
Two, 3.2 dia.
Holes
10.3
18.7
(9.4)
16
70
Mounting Holes
2-M3
3.4
4.4
Vinyl-insulated round cable
Standard length: 2 m ✽2
12.5
Hole for optical communications
4.3
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
16
28.1
16
Fiber Attachment mounted (E39-F9)
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the
Amplifier Units if they are mounted side by side.
✽2. The cable specifications are as follows:
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA21F-S
E3X-DA51F-S
4 dia. cable / 5 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
4 dia. cable / 3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
23