English
Language : 

E3X-DA-S Datasheet, PDF (15/28 Pages) Omron Electronics LLC – Digital Fiber Sensors
4 Teaching the Threshold (SET Mode)
✽ There are five methods that can be used for teaching, as described
below. Use the method most suitable for the application.
✽ Two-point teaching, positioning teaching, and automatic teaching
can be performed in RUN Mode.
For operating procedures, refer to the Instruction Manual provided
with the product.
✽ An error has occurred if OVER or LO is displayed on the
sub-display. If that occurs, repeat the operation from the beginning.
4-1. Setting the Threshold at Maximum Sensitivity
The threshold can be set to the maximum sensitivity.
This is useful when the longest detection distance is
required.
Set the SET/RUN Mode
Selector Switch to SET.
SET
Incident level
Threshold
With no workpiece:
The threshold that
was set will flash twice.
FULL
UP
DOWN
Press
either
for 3 s.
Threshold
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
Incident level
Threshold
4-2. Teaching a Through-beam Fiber Unit without a Workpiece
You can set the threshold to below the incident light level
without a workpiece by the percentage set for the teaching
level.
➜Refer to 5. Setting Functions on page 16.
Set the SET/RUN Mode
Selector Switch to SET.
SET
Incident level
Threshold
With no workpiece:
"----" will be displayed.
UP
DOWN
Press
either
for 1 s.
TECH
----
The threshold that
THRU
was set will flash twice.
RUN
To RUN
Threshold
This completes the
setting procedure.
Incident level
Threshold
E3X-DA-S
4-3. Teaching a Reflective Fiber Unit without a Workpiece
You can set the threshold to above the incident light level without
a workpiece by the percentage set for the teaching level.
➜Refer to 5. Setting Functions on page 16.
Set the SET/RUN Mode
Selector Switch to SET.
SET
Incident level
Threshold
With no workpiece:
"----" will be displayed.
UP
DOWN
Press
either
for 1 s.
TECH
----
The threshold that
was set will flash twice.
UP
DOWN
Press
either
for 3 s.
RFCT
Threshold
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
Incident level
Threshold
4-4. Two-point Teaching
4-5. Positioning Teaching
Two points in the following figures are detected, and
the intermediate point of the light levels for the
two points is set as the threshold.
Set the SET/RUN Mode
Selector Switch to SET.
SET
Incident level
Threshold
With a workpiece:
For positioning
UP
DOWN
teaching, place the
workpiece where
you want to
position it.
Workpiece
TECH
----
"----" will be displayed.
Press
either
for 1 s.
With no workpiece:
For positioning
teaching, place the
workpiece where
you want to
position it.
The threshold that
was set will flash twice.
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
UP
DOWN
Press
either
for 1 s.
2PNT
Threshold
Incident level
Threshold
15