English
Language : 

E3X-DA-S Datasheet, PDF (5/28 Pages) Omron Electronics LLC – Digital Fiber Sensors
E3X-DA-S
Sensing Distance
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
Screw-shaped model
Sensing
method
Size
Sensing
direction
Model
Tough mode
M3
Straight
E32-T21R 2M
450
Through-
beam
models
M4
Right angle
Straight
E32-T11N 2M
E32-T11R 2M
E32-TC200 2M
2,000
2,000
2,800
E32-T11L 2M
4,000 ✽
Right angle E32-C31N 2M
110
M3
E32-D21R 2M
140
Straight
E32-C31 2M
330
M4
E32-D211R 2M
140
Reflective
models
Right angle
E32-D11N 2M
E32-C11N 2M
840
780
E32-D11R 2M
M6
E32-DC200 2M
Straight
E32-CC200 2M
840
1,400
1,400
E32-D11L 2M
1,820
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution Standard
mode
mode
High-speed
mode
300
250
150
1,400
1,000
700
1,400
1,000
700
2,000
1,550
1,000
3,400
2,700
1,740
80
50
46
100
60
40
240
150
100
100
60
40
600
350
240
560
350
320
600
350
240
1,000
600
400
1,000
600
400
1,300
800
520
Super-high-
speed mode
60
280
280
400
700
14
16
44
16
100
100
100
180
180
220
Fiber Unit
Flat model
Sensing
method
Through-
beam
models
Sensing
direction
Top view
Side view
Flat view
Reflective
models
Top view
Side view
Flat view
Size
Standard
Small
Standard
Small
Standard
Small
Standard
Small
Standard
Small
Standard
Small
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T15XR 2M
2,000
1,400
1,000
700
280
E32-T25XR 2M
450
300
250
150
60
E32-T15YR 2M
750
550
450
260
100
E32-T25YR 2M
170
120
100
50
20
E32-T15ZR 2M
750
550
450
260
100
E32-T25ZR 2M
170
120
100
50
20
E32-D15XR 2M
840
600
350
240
100
E32-D25XR 2M
140
100
60
40
16
E32-D15YR 2M
200
140
100
52
24
E32-D25YR 2M
40
28
16
10
4
E32-D15ZR 2M
200
140
100
52
24
E32-D25ZR 2M
40
28
16
10
4
Fiber Unit
Cylindrical model
Sensing
method
Sensing
direction
Through-
beam
models
Top view
Side view
Reflective
models
Top view
Side view
Size
φ1
φ3
φ1
φ3
φ1.5
φ2
φ3
φ2
φ6
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T223R 2M
450
300
250
150
60
E32-T12R 2M
2,000
1,400
1,000
700
280
E32-T24R 2M
170
120
100
50
20
E32-T14LR 2M
750
550
450
260
100
E32-D22B 2M
140
100
60
40
16
E32-D32 2M
330
240
150
100
44
E32-D22R 2M
140
100
60
40
16
E32-D32L 2M
700
500
300
200
90
E32-D24R 2M
70
52
30
20
8
E32-D14LR 2M
220
160
100
60
28
Fiber Unit
Model equipped with sleeve
Sensing
method
Sleeve size
Mounting size
φ0.25 × 5
Through-
φ0.5 × 40
φ3
beam
models
φ0.9 × 40
M3
φ1.2 × 90
M4
φ0.5 × 15
φ2
Reflective φ0.8 × 15
φ3
models
φ1.2 × 40
M3
φ2.5 × 90
M6
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed Super-high-
mode
speed mode
E32-T333-S5 1M
35
25
20
12
8
E32-T33 1M
150
110
90
50
20
E32-TC200F4R 2M
450
300
250
150
60
E32-TC200BR 2M
2,000
1,400
1,000
700
280
E32-D331 2M
14
10
6
4
2
E32-D33 2M
70
50
30
20
8
E32-DC200F4R 2M
140
100
60
40
16
E32-DC200BR 2M
840
600
350
240
100
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).