English
Language : 

E3X-DA-S Datasheet, PDF (10/28 Pages) Omron Electronics LLC – Digital Fiber Sensors
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Movable section (Flexibility)
Sensing
method
Type
Through-
beam
models
Screw-shaped
model
Cylindrical
model
Flat model
Reflective
models
Screw-shaped
model
Cylindrical
model
Flat model
Size
M3
M4
φ1.5
φ3
Standard
Small
M3
M4
M6
φ1.5
φ3
Standard
Small
Amplifier Unit
Model
E32-T21 2M
E32-T11 2M
E32-T22B 2M
E32-T12B 2M
E32-T15XB 2M
E32-T25XB 2M
E32-D21 2M
E32-D21B 2M
E32-D11 2M
E32-D22B 2M
E32-D221B 2M
E32-D15XB 2M
E32-D25XB 2M
Tough mode
340
1,250
340
1,250
1,250
250
70
150
420
70
150
420
120
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution Standard High-speed
mode
mode
mode
240
200
110
900
680
450
240
200
110
900
680
450
900
680
450
180
150
85
50
30
20
110
70
45
300
170
120
50
30
20
110
70
45
300
170
120
85
50
30
Super-high-
speed mode
45
180
45
180
180
35
8
20
50
8
20
50
15
Fiber Unit
Amplifier Unit
Heat-resistance model
Sensing Operating
method temperature
Lens
Model
Tough mode
---
E32-T51R 2M
800
100°C
Lens
E32-T51R 2M + E39-F1
4,000 ✽
High-power lens E32-T51R 2M + E39-F16
4,000 ✽
---
E32-T51 2M
1,400
Through-
beam
models
150°C
Lens
High-power lens
---
E32-T51 2M + E39-F1-33
E32-T51 2M + E39-F16
E32-T54 2M
E32-T81R-S 2M
4,000 ✽
4,000 ✽
420
500
200°C
E32-T61-S 2M
840
Lens
E32-T61-S 2M + E39-F1
4,000 ✽
350°C
---
E32-T61-S 2M
High-power lens E32-T61-S 2M + E39-F16
840
4,000 ✽
100°C
E32-D51R 2M
330
150°C
E32-D51 2M
560
Reflective
models
200°C
---
E32-D81R 2M
210
350°C
E32-D61 2M
210
400°C
E32-D73 2M
140
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution Standard High-speed
mode
mode
mode
560
425
280
3,900
2,900
1,900
4,000 ✽
4,000 ✽
3,600
1,000
760
500
3,400
2,660
1,150
4,000 ✽
4,000 ✽
4,000 ✽
300
230
150
360
280
180
600
450
300
4,000 ✽
3,400
2,200
600
450
300
4,000 ✽
4,000 ✽
3,900
240
135
95
400
230
160
150
90
60
150
90
60
100
60
40
Super-high-
speed mode
110
760
1,400
200
700
2,600
60
70
120
900
120
1,500
40
72
27
27
18
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Chemical-resistance / Oil-resistance model
Sensing distance (unit: mm)
Sensing
method
Type
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
φ5
E32-T12F 2M
4,000 ✽1
4,000 ✽1
3,000
2,000
φ7.2
E32-T11F 2M
3,500
2,500
2,000
1,300
Through-
beam
models
φ5
Heat-resistance model
φ5
Side view
M4
Chemical-resistance cable
E32-T51F 2M
E32-T14F 2M
E32-T11U 2M
2,500
1,800
1,400
900
700
500
400
250
1,250
900
680
450
M4
Right angle Chemical-resistance cable
E32-T11NU 2M
720
520
400
260
φ6
E32-D12F 2M
--- ✽2
160
95
65
Reflective
models
φ7
Side view
M6
Chemical-resistance cable
E32-D14F 2M
E32-D11U 2M
--- ✽2
70
40
30
420
300
170
120
✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
✽2. The sensor will detect light even if there is no sensing object, and so Tough Mode cannot be used.
Super-high-
speed mode
800
520
350
100
180
100
30
10
50
Fiber Unit
Vacuum-resistance model
Sensing Operating ambient
method
temperature
Through-
beam
models
120°C
200°C
Sensing
direction
Top view
Right angle
Amplifier Unit
Model
E32-T51V 1M
E32-T51V 1M + E39-F1V
E32-T54V 1M
E32-T84SV 1M
Tough mode
360
1,890
290
880
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution Standard High-speed
mode
mode
mode
260
200
130
1,350
1,000
680
210
130
100
630
480
320
Super-high-
speed mode
50
260
35
130
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
10