English
Language : 

CCU3000 Datasheet, PDF (37/77 Pages) Micronas – Central Control Unit
CCU 3000, CCU 3000-I
CCU 3001, CCU 3001-I
4.6.9. Recommended Operating Conditions of IM Bus
Symbol
VIML
VIMH
Rext
IIMOL
fΦI
tIM1
tIM2
tIM3
tIM4
tIM5
tIM6
tIM7
tIM8
tIM9
tIM10
Parameter
IM bus Low Voltage
IM bus High Voltage
External Pull-Up Resistor
IM bus Output Low Current
ΦI IM bus Clock Frequency
ΦI Clock Delay Time
after IM bus Ident
ΦI Clock Low Pulse Time
ΦI Clock High Pulse Time
ΦI Clock Setup Time
before Ident High
ΦI Clock Hold Time
after Ident High
ΦI Clock Setup Time
before Ident End-Pulse
IM bus Data Delay Time
after ΦI Clock
IM bus Data Setup Time
before ΦI Clock
IM bus Data Hold Time
after ΦI Clock
IM bus Ident
End-Pulse Low Time
Pin No.
Data
7, 10
Clock
9, 12
Min.
–
2.4
1
–
0.05
>0
500
500
>0
250
1
>0
Clock,
>0
Data
7, 9, 10,
12
>0
Ident
1
8, 11
Typ.
–
–
–
–
–
–
Max.
0.8
–
2.5
5
1000
–
–
–
–
–
0.5 ⋅ tIM3 –
0.5 ⋅ tIM3 –
tIM2 +tIM3 –
–
–
–
–
–
–
tIM2 +tIM3 –
Unit
V
V
kΩ
mA
kHz
–
ns
ns
ns
ns
µs
ns
ns
ns
µs
MICRONAS INTERMETALL
37