4.6. Electrical Characteristics
All voltages refer to ground.
4.6.1. Absolute Maximum Ratings
Symbol
TA
TS
VSUP
VI
Pmax
Parameter
Ambient Operating Temperature
Storage Temperature
Supply Voltage
Input Voltage
Maximum Power Dissipation
Pin
â
â
1
4, 6, 16,
13 to 25,
42 to 68
â
Min.
0
â40
â0.5
â0.3 V
â
Max.
65
+125
6
VSUP+0.3 V
Unit
°C
°C
V
â
500
mW
The total sum of all the sink currents of all ports together must not exceed 80 mA Ioutlow and 280 mA â Iout high at any
time. Stresses beyond those listed in the âAbsolute Maximum Ratingsâ may cause permanent damage to the device.
This is a stress rating only. Functional operation of the device at these or any other conditions beyond those indicated
in the âRecommended Operating Conditions/Characteristicsâ of this specification is not implied. Exposure to absolute
maximum ratings conditions for extended periods may affect device reliability.
4.6.2. Recommended Operating Conditions at TA = 0 °C to 65°C
Symbol
VSUP
fCLK
Parameter
Supply Voltage
Clock Frequency
Pin
Min.
Typ.
Max.
Unit
1
4.75
â
5.25
V
3, 4
0.5
â
8
MHz
4.6.3. Recommended Crystal Characteristics at CXTAL1 = CXTAL2 = 22 pF; Cstray ⤠2 pF; CL â13 pF
Symbol
TA
fp
Rr
C0
C1
P
fp / fH
Parameter
Ambient Operating Temperature
Parallel Resonance Frequency
@ CL = 13 pF
Series Resistance
Shunt Capacitance
Motional Capacitance
Rated Drive Level
Spurious Frequency Attenuation
Min.
â20
â
â
â
â
â
20
Typ.
â
4â8
â
â
â
0.02
â
Max.
+85
â
40 [8MHz]
150 [4 MHz]
7.0
20
â
â
Unit
°C
MHz
â¦
pF
fF
mW
dB
32