English
Language : 

CCU3000 Datasheet, PDF (32/77 Pages) Micronas – Central Control Unit
CCU 3000, CCU 3000-I
CCU 3001, CCU 3001-I
4.6. Electrical Characteristics
All voltages refer to ground.
4.6.1. Absolute Maximum Ratings
Symbol
TA
TS
VSUP
VI
Pmax
Parameter
Ambient Operating Temperature
Storage Temperature
Supply Voltage
Input Voltage
Maximum Power Dissipation
Pin
–
–
1
4, 6, 16,
13 to 25,
42 to 68
–
Min.
0
–40
–0.5
–0.3 V
–
Max.
65
+125
6
VSUP+0.3 V
Unit
°C
°C
V
–
500
mW
The total sum of all the sink currents of all ports together must not exceed 80 mA Ioutlow and 280 mA – Iout high at any
time. Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress rating only. Functional operation of the device at these or any other conditions beyond those indicated
in the “Recommended Operating Conditions/Characteristics” of this specification is not implied. Exposure to absolute
maximum ratings conditions for extended periods may affect device reliability.
4.6.2. Recommended Operating Conditions at TA = 0 °C to 65°C
Symbol
VSUP
fCLK
Parameter
Supply Voltage
Clock Frequency
Pin
Min.
Typ.
Max.
Unit
1
4.75
–
5.25
V
3, 4
0.5
–
8
MHz
4.6.3. Recommended Crystal Characteristics at CXTAL1 = CXTAL2 = 22 pF; Cstray ≤ 2 pF; CL ≈13 pF
Symbol
TA
fp
Rr
C0
C1
P
fp / fH
Parameter
Ambient Operating Temperature
Parallel Resonance Frequency
@ CL = 13 pF
Series Resistance
Shunt Capacitance
Motional Capacitance
Rated Drive Level
Spurious Frequency Attenuation
Min.
–20
–
–
–
–
–
20
Typ.
–
4–8
–
–
–
0.02
–
Max.
+85
–
40 [8MHz]
150 [4 MHz]
7.0
20
–
–
Unit
°C
MHz
Ω
pF
fF
mW
dB
32
MICRONAS INTERMETALL